RESTful API Reference

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50

This document describes the OPS APIs supported by the device, including OPS-supported operations, request examples, elements in the requests, response examples, elements in the responses, and response status codes.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SNMP Engine ID

SNMP Engine ID

Configure an SNMP Engine ID

Operation

URI

Description

PUT

/snmp/engine

Configure an SNMP engine ID.

  • Request example:
    <?xml version="1.0" encoding="UTF-8"?>
    <engine>
      <version>all</version>
      <engineID>abc11111111</engineID>
      <engineMaxMessageSize>11150</engineMaxMessageSize>
    </engine>

    Table 3-306 describes elements in requests.

    Table 3-306  Elements

    Element

    Description

    version

    Specifies an SNMP version.

    engineID

    Specifies an SNMP engine ID.

    engineMaxMessageSize

    Specifies the maximum size of an SNMP packet that can be received and sent by a device.

  • Response example (XML format)
    <?xml version="1.0" encoding="UTF-8"?>
    <ok/>

    Table 3-307 describes status codes in responses.

    Table 3-307  Status codes

    Status Code

    Description

    200 OK

    The operation succeeded.

    400 Bad Request

    The request operation failed because the request is incorrect in syntax or the information attribute in the request is incorrect.

    500 Internal Server Error

    The request operation failed because of internal errors in services or unidentified processing errors.

Query an SNMP Engine ID

Operation

URI

Description

GET

/snmp/engine

Query an SNMP engine ID.

  • Request example
    <?xml version="1.0" encoding="UTF-8"?>
    <engine>
        <version/>
        <engineID/>
        <engineMaxMessageSize/>
    </engine>

    Table 3-308 describes elements in requests.

    Table 3-308  Elements

    Element

    Description

    version

    Specifies an SNMP version.

    engineID

    Specifies an SNMP engine ID.

    engineMaxMessageSize

    Specifies the maximum size of an SNMP packet that can be received and sent by a device.

  • Response example (XML format)
    <?xml version="1.0" encoding="UTF-8"?>
    <engine>
        <version>all</version>
        <engineID>800007DB03D8490BB5E087</engineID>
        <engineMaxMessageSize>12000</engineMaxMessageSize>
    </engine>

    Table 3-309 describes elements in responses.

    Table 3-309  Elements

    Element

    Description

    version

    Specifies an SNMP version.

    engineID

    Specifies an SNMP engine ID.

    engineMaxMessageSize

    Specifies the maximum size of an SNMP packet that can be received and sent by a device.

    Table 3-310 describes status codes in responses.

    Table 3-310  Status codes

    Status Code

    Description

    200 OK

    The operation succeeded.

    400 Bad Request

    The request operation failed because the request is incorrect in syntax or the information attribute in the request is incorrect.

    500 Internal Server Error

    The request operation failed because of internal errors in services or unidentified processing errors.

Translation