Configuration Guide - IP Unicast Routing

CloudEngine 12800 and 12800E V200R002C50

This document describes the configurations of IP Unicast Routing, including IP Routing, Static Route, RIP, RIPng, OSPF, OSPFv3, IPv4 IS-IS, IPv6 IS-IS, BGP, Routing Policy, and PBR.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting the Maximum Number of Equal-Cost Routes

Setting the Maximum Number of Equal-Cost Routes

Context

By setting the maximum number of equal-cost RIP routes, you can change the number of routes for load balancing.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run rip [ process-id ]

    The RIP view is displayed.

  3. Run maximum load-balancing number

    The maximum number of equal-cost routes is set. The default value is 64.

  4. Run commit

    The configuration is committed.