Configuration Guide - Reliability

CloudEngine 12800 and 12800E V200R002C50

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, EFM Configuration, and CFM Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Associating EFM with an Interface

Associating EFM with an Interface

Usage Scenario

A device is usually connected to an IP network over the primary and backup links to improve network robustness and service reliability. EFM can be associated with interfaces. On a scenario with primary and backup links, if EFM detects a fault on the primary link, it will set the protocol status of the associated interface to EFM Down, speeding up routing convergence. Traffic can be fast switched to the backup link.

After EFM is associated with an interface, you can adjust the delay in changing the EFM status of an interface from Down to Up by setting the time during which the EFM status of the interface remains Down, if a link connectivity fault is rectified.

Pre-configuration Tasks

Before associating EFM with an interface, Configuring Basic EFM Functions.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The view of the interface at one end of a link is displayed.

  3. Run efm trigger if-down

    EFM is associated with the interface.

    By default, EFM is not associated with any interface.

  4. (Optional) Run efm holdup-timer time

    The time during which the EFM status of the interface remains Down is set.

    The default time is 0 seconds.

    If the parameter time is not specified, the EFM status of an interface immediately changes from Down to Up when a link connectivity fault is rectified. If the parameter time is specified, the EFM status of an interface changes from Down to Up only when a link connectivity fault is rectified and after the time specified by the parameter time elapses. Setting the parameter time can reduce link flapping. You can run the recover efm-down command to change the EFM status of an interface from Down to Up.

  5. Run commit

    The configuration is committed.

Translation
Download
Updated: 2019-03-21

Document ID: EDOC1000166606

Views: 126671

Downloads: 90