Configuration Guide - Virtualization

CloudEngine 12800 and 12800E V200R002C50

This document describes the configurations of virtualization, including stack and VS.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Ports Excluded from Shutdown When a Stack Has No Forwarding Link

Configuring Ports Excluded from Shutdown When a Stack Has No Forwarding Link

Context

In MPU connection mode, if there is no forwarding link between two member devices, service ports of one member device enter the error-down state.
  • If two member devices are connected through the forwarding link when setting up a stack or the forwarding link has not been Up after a stack is set up, service ports on the standby switch enter the error-down state.

  • If the forwarding link changes from Up to Down, service ports on the member device with fewer LPUs enter the error-down state. If the two member devices have the same number of LPUs, service ports on the standby switch enter the error-down state.

To retain services on some ports, configure these ports as ports excluded from shutdown. These ports then will not set to error-down state.
NOTE:
  • This function can be configured only when the stack connection mode is MPU connection.

  • Physical member ports cannot be configured as ports excluded from shutdown. Ports excluded from shutdown cannot be configured as physical member ports either.

Procedure

  1. Run the system-view command to enter the system view.
  2. Run the stack command to enter the stack management view.
  3. Run the no-stack-link exclude interface interface-type { interface-number1 [ to interface-number2 ] } &<1-32> command to configure ports excluded from shutdown.

    By default, no port is configured as a port excluded from shutdown.

  4. Run the commit command to commit the configuration.