Configuration Guide - Virtualization

CloudEngine 12800 and 12800E V200R002C50

This document describes the configurations of virtualization, including stack and VS.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring an Alarm Threshold for the Number of Stack Links

Configuring an Alarm Threshold for the Number of Stack Links

Context

In a stack, multiple physical member ports can be added to the same stack port to improve stack link bandwidth and reliability.

To ensure stack link bandwidth and reliability, set the alarm threshold for the number of stack links. When some stack links become faulty, the system sends an alarm if the number of available stack links is smaller than the alarm threshold. When the number of available stack links is greater than or equal to the alarm threshold, the system sends a clear alarm.

Procedure

  1. Run the system-view command to enter the system view.
  2. Run the stack command to enter the stack management view.
  3. Run the stack port-link threshold alarm-threshold command to set an alarm threshold for the number of stack links.

    By default, the alarm threshold for the number of stack links is 1.

  4. Run the commit command to commit the configuration.