No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50 Configuration Guide - Virtualization

This document describes the configurations of virtualization, including stack and SVF.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Monitoring the Stack Status

Monitoring the Stack Status

Context

To ensure normal system operations or locate faults that occur in the stack, run the following command in any view to monitor the stack running status.

Procedure

  • Run the display stack [ member member-id ] command to check information about stack member switches.
  • Run the display stack configuration [ member member-id | all ] command to check the stack configuration.
  • Run the display stack topology [ link | neighbor ] command to check stack topology information.
  • Run the display stack troubleshooting [ member member-id ] [ history ] command to check the stack fault events.
  • Run the display stack link-state last-down-reason command to check why the stack link protocol becomes Down.
  • Run the display stack blocked-interface [ member member-id ] command to check packet congestion information on stack ports in a stack.