No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CloudEngine 8800, 7800, 6800, and 5800 V200R002C50 Configuration Guide - Virtualization

This document describes the configurations of virtualization, including stack and SVF.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Example for Configuring DAD in Relay Mode on Eth-Trunk

Example for Configuring DAD in Relay Mode on Eth-Trunk

Networking Requirements

As shown in Figure 1-35, SwitchA and SwitchB set up a stack and connect to the upstream and downstream devices through Eth-Trunk. It is expected that stack split detection will be performed through Eth-Trunk.

Figure 1-35 DAD in relay mode on an Eth-Trunk

Configuration Roadmap

The configuration roadmap is as follows:
  1. Use SwitchC as a DAD relay agent. On the stack, configure DAD in relay mode on Eth-Trunk10 connected to SwitchC.

  2. On SwitchC, enable the DAD proxy function on Eth-Trunk10 so that DAD packets can be forwarded through Eth-Trunk10.

    NOTE:

    To enable DAD packets to be forwarded over Eth-Trunk member links, use a switch that supports the DAD proxy function as the relay agent. All Huawei CloudEngine series switches support the DAD proxy function. Huawei S series switches support this function since V200R003C00. On S series switches, DAD is also called multi-active detection (MAD).

Procedure

  1. On the stack, configure DAD in relay mode on Eth-Trunk10.

    <HUAWEI> system-view
    [~HUAWEI] interface eth-trunk 10
    [*HUAWEI-Eth-Trunk10] trunkport 10ge 1/0/5
    [*HUAWEI-Eth-Trunk10] trunkport 10ge 2/0/5
    [*HUAWEI-Eth-Trunk10] dual-active detect mode relay
    [*HUAWEI-Eth-Trunk10] commit
    [~HUAWEI-Eth-Trunk10] return
    

  2. On SwitchC, enable the DAD proxy function on Eth-Trunk10.

    <HUAWEI> system-view
    [~HUAWEI] sysname SwitchC
    [*HUAWEI] commit
    [~SwitchC] interface eth-trunk 10
    [*SwitchC-Eth-Trunk10] trunkport 10ge 1/0/1
    [*SwitchC-Eth-Trunk10] trunkport 10ge 1/0/2
    [*SwitchC-Eth-Trunk10] dual-active proxy
    [*SwitchC-Eth-Trunk10] commit
    [~SwitchC-Eth-Trunk10] return
    

  3. Verify the configuration.

    # Check the detailed DAD configuration on the stack.

    <HUAWEI> display dual-active
    Stack domainID: 10
    Dual-active status: Normal
    Dual-active detect mode: Relay
    Dual-active detect configuration of MEth: Disable
    Dual-active direct detect interfaces configured:
     --
    Dual-active relay detect interfaces configured:
     Eth-Trunk10
       10GE1/0/5       up  (Physical)  up  (Protocol)  10   (PeerDomain)
       10GE2/0/5       up  (Physical)  up  (Protocol)  10   (PeerDomain)
    Excluded ports(configurable):
     --
    Excluded ports(can not be configured):
     10GE1/0/1
     10GE1/0/2
     10GE1/0/3
     10GE1/0/4
     10GE2/0/1
     10GE2/0/2
     10GE2/0/3
     10GE2/0/4
    

    # Check DAD proxy information on SwitchC.

    <SwitchC> display dual-active proxy
    Dual-active proxy interfaces configured:
     Eth-Trunk10
          10GE1/0/1        up
          10GE1/0/2        up
    

  4. Verify the DAD function.

    After the DAD function is configured:
    • If a stack split occurs, the alarm "DAD_1.3.6.1.4.1.2011.5.25.246.1.1 hwDadConflictDetect" is generated.
    • If the stack recovers from a split, the alarm "DAD_1.3.6.1.4.1.2011.5.25.246.1.2 hwDadConflictResume" is generated.
    If no service is configured in the stack, simulate a stack split situation to check whether the DAD function is configured successfully.

    Do not trigger a stack split when services are running on the stack. Otherwise, services are affected.

    1. Trigger a stack split by disabling all ports with stack cables connected or removing all stack cables.

    2. Run the display stack command to check whether the number of stack member switches reduces. If so, the stack has split.

    3. Run the display trapbuffer command to check whether there are DAD alarms.
      <HUAWEI> display trapbuffer
      ......
      
      Aug 15 2016 14:32:35 HUAWEI %%01DAD/1/hwDadConflictDetect(t):CID=0x807f0419-OID=1.3.6.1.4.1.2011.5.25.246.1.1;Dual-active scenario is detected.
      
    4. The preceding operations verify that the DAD function has been configured successfully.

    5. Restore the stack by enabling all ports used for stack connections or reconnecting stack cables so that the stack can be set up again.

Configuration Files

  • Stack configuration file

    #
    interface 10GE1/0/5
     eth-trunk 10
    #
    interface 10GE2/0/5
     eth-trunk 10
    #
    interface Eth-Trunk10
     dual-active detect mode relay
    #
    return
    
  • SwitchC configuration file

    #
    sysname SwitchC
    #
    interface 10GE1/0/1
     eth-trunk 10
    #
    interface 10GE1/0/2
     eth-trunk 10
    #
    interface Eth-Trunk10
     dual-active proxy
    #
    return
    
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1000166645

Views: 55418

Downloads: 344

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next