Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Alarm Thresholds

Configuring Alarm Thresholds

Context

Configure alarm thresholds to monitor the network. After monitoring conditions are configured, the device sends alarms to the NMS when the monitored item in the test result exceeds the configured upper or lower threshold. The alarms enable you to monitor the real-time operating status of the network.

You can also configure an action for the system to perform when a monitored item exceeds the threshold. The system can record a log, generate an alarm, or performs both depending on the configuration.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run nqa event event-entry { log | trap | log-trap | linkage admin-name test-name | none } [ description ]

    An event is associated with the NQA alarm.

    By default, no event is associated with the NQA alarm.

  3. Run nqa test-instance admin-name test-name

    The NQA view is displayed.

  4. Run alarm entry-number { jitter-average | jitter-ds-average | jitter-sd-average | lost-packet-ratio | packet-loss-ds | packet-loss-sd | rtt-average } { absolute | delta } { falling-threshold threshold-value1 event-entry1 | rising-threshold threshold-value2 event-entry2 } * [ description description ]

    The thresholds for triggering alarms for the associated events are configured.

    By default, no threshold for triggering alarms is set.

    NOTE:
    • Parameters jitter-average, jitter-ds-average, jitter-sd-average, packet-loss-ds, and packet-loss-sd can be configured only for jitter test instances.
    • At present, the device supports only the absolute statistics function but not the relative statistics function.