Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the TWAMP Light Responder

Configuring the TWAMP Light Responder

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run nqa twamp-light

    The TWAMP Light service is created and the TWAMP Light view is displayed.

    By default, the TWAMP Light service is not created.

  3. Run responder

    The TWAMP Light Responder function is enabled and the TWAMP Light Responder view is displayed.

    By default, the TWAMP Light Responder function is disabled.

  4. Run test-session session-id local-ip local-ip-address remote-ip remote-ip-address local-port local-port remote-port remote-port [ vpn-instance vpn-instance-name ] [ description description ]

    A measurement session is created on the responder.

    By default, no measurement session is created on the responder.

    • After a session is created, its parameters cannot be modified. To modify the session parameters, delete the session and create it again.

    • The IP address must be a unicast address.

    • The UDP port of the sender must be a port that is not occupied.

    • All the parameters related to the VPN instance must exist. When the VPN instance is deleted, the related measurement instance is also deleted.