No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
WLAN_1.3.6.1.4.1.2011.6.139.13.1.1.17 hwApTemperatureTooLowTrap

WLAN_1.3.6.1.4.1.2011.6.139.13.1.1.17 hwApTemperatureTooLowTrap

Description

WLAN/4/AP_TEMPERATURE_TOO_LOW:OID [oid] The AP's temperature is too low. (AP Mac=[OPAQUE], APName=[STRING], Temperature=[INTEGER]°C, APID=[INTEGER])

The AP's temperature is lower than the lower temperature threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.6.139.13.1.1.17 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the ID of the MIB object.
AP Mac Indicates the MAC address of an AP.
APName Indicates the AP name.
Temperature Indicates the temperature of the AP.
APID Indicates the AP ID.

Impact on the System

The AP's temperature is lower than the lower temperature threshold.
  • If the lower temperature threshold is not low, the low AP temperature has no impact on services.
  • If the lower temperature threshold is low, the AP cannot work properly, affecting WLAN services.

Possible Causes

1:

The lower temperature threshold is set to an improper value.

2:

The ambient temperature is too low.

Procedure

  1. Run the display ap-system-profile { all | name profile-name } command to check whether the lower temperature threshold is set properly.

    • If so, go to Step 3.
    • If not, go to Step 2.

  2. Run the low-temperature threshold min-temperature command to set a proper lower temperature threshold.

    • If the alarm persists, go to Step 3.
    • If the alarm is cleared, go to Step 5.

  3. Increase the ambient temperature by turning up air-conditioners.

    • If the alarm persists, go to Step 4.
    • If the alarm is cleared, go to Step 5.

  4. Collect alarm messages, log messages, and configurations, and then contact the technical support personnel.
  5. End.
Translation
Download
Updated: 2019-05-06

Document ID: EDOC1000174085

Views: 121925

Downloads: 20

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next