Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.83 hwMplsTeLspBfdDown

LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.83 hwMplsTeLspBfdDown

Description

LSPM/2/MPLSTELSPBFDDOWN: OID [oid] The status of BFD for TE LSP changed to down.(SessionTunnelId=[integer], LocalLspId=[integer], IngressLsrId=[integer], EgressLsrId=[integer], TunnelName=[OCTET], LspRole=[integer])

BFD detected a TE LSP fault.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.121.2.1.83

Major

communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

SessionTunnelId

Tunnel ID

LocalLspId

Local LSP ID

IngressLsrId

LSR ID of the ingress

EgressLsrId

Egress LSR ID

TunnelName

Tunnel name

LspRole

LSP type

Impact on the System

Traffic to be transmitted over the faulty TE LSP is interrupted.

Possible Causes

BFD detected a TE LSP fault.

Procedure