Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NQA_1.3.6.1.4.1.2011.5.25.111.6.20 nqaRisingAlarmNotification

NQA_1.3.6.1.4.1.2011.5.25.111.6.20 nqaRisingAlarmNotification

Description

NQA/3/RISING_TRAP: OID [oid] The sampling value of alarming in the alarm table is over rising-threshold or equal to rising-threshold. (OwnerIndex=[OCTET], TestName=[OCTET], AlarmEntryNumber=[INTEGER],alarm value=[INTEGER], alarm sampling type=[INTEGER], sampling value=[INTEGER], rising-threshold=[INTEGER])

The value of the monitored node was greater than the upper threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.111.6.20

Minor

communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

OwnerIndex

Indicates the name of the administrator for an NQA test instance.

TestName

Indicates the name of an NQA test instance.

AlarmEntryNumber

Indicates the index of a trap entry.

alarm value

Indicates the monitored trap variable.

alarm sampling type

Indicates the type of the sampled alarm:
  • 1: Average round trip delay
  • 2: Packet loss ratio
  • 3: Number of packets discarded from the source to the destination
  • 4: Number of packets discarded from the destination to the source
  • 5: Average jitter value
  • 6: Average jitter value from the source to the destination
  • 7: Average jitter value from the destination to the source.

sampling value

Indicates the sample value.

rising-threshold

Indicates the upper threshold.

Impact on the System

None.

Possible Causes

The value of the monitored node was greater than the upper threshold.

Procedure

  1. Run the display nqa-agent command in the user view and check the type of the sampled alarm. Run the display nqa results command based on this type and check the test result. Check whether the upper threshold is set too low.

    • If the upper threshold is set too low, go to step 2.
    • If the upper threshold is proper, go to Step 3.

  2. Run the alarm command to set a proper upper threshold.

    Perform the test again to check whether the alarm is cleared.
    • If the alarm is cleared, go to step 5.
    • If the alarm persists, go to Step 3.

  3. The alarm is triggered due to the entire network. Therefore, check that network configurations and services are proper. Then check whether the alarm is cleared.

    • If the alarm is cleared, go to step 5.
    • If the alarm persists, go to Step 4.

  4. Collect alarm information and configuration information, and then contact technical support personnel.
  5. End.