EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.36 hwDot1agCfmUnexpectedMEP
Description
EOAM1AG/3/UNEXPECTEDMEP: OID [oid] MEP received a CCM with unexpected MEP. (MdIndex=[GAUGE], MaIndex=[GAUGE], MdName=[STRING], MaName=[STRING], MepId=[INTEGER])
The MEP ID carried in a CCM sent by the RMEP was not listed in the RMEP list of the MEP.
Attribute
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.136.1.6.36 | Minor | communicationsAlarm(2) |
Parameters
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
MdIndex |
Index of an MD table |
MaIndex |
Index of an MA table |
MdName |
Name of an MD |
MaName |
Name of an MA |
MepId |
ID of a MEP |
Possible Causes
The MEP ID carried in a received CCM was not listed in the RMEP list of the MEP when the MEP and RMEP have the same MD level and MA ID.
Procedure
- Run the display cfm remote-mep [ md md-name ma ma-name mep-id mep-id ] command on the MEP to view the value of the RMEP ID field. Check whether the RMEP ID is displayed in the command output.
- Perform the following steps on the MEP:
- Run the remote-mep mep-id mep-id [ mac mac-address ] command to specify a correct RMEP.
- Run the display alarm active command to view the trap. Check whether the trap is cleared. If the trap persists, go to Step 3.
- Collect alarm information and configuration information, and then contact technical support personnel.