Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.36 hwDot1agCfmUnexpectedMEP

EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.36 hwDot1agCfmUnexpectedMEP

Description

EOAM1AG/3/UNEXPECTEDMEP: OID [oid] MEP received a CCM with unexpected MEP. (MdIndex=[GAUGE], MaIndex=[GAUGE], MdName=[STRING], MaName=[STRING], MepId=[INTEGER])

The MEP ID carried in a CCM sent by the RMEP was not listed in the RMEP list of the MEP.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.136.1.6.36 Minor communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

MdIndex

Index of an MD table

MaIndex

Index of an MA table

MdName

Name of an MD

MaName

Name of an MA

MepId

ID of a MEP

Impact on the System

CFM will fail.

Possible Causes

The MEP ID carried in a received CCM was not listed in the RMEP list of the MEP when the MEP and RMEP have the same MD level and MA ID.

Procedure

  1. Run the display cfm remote-mep [ md md-name ma ma-name mep-id mep-id ] command on the MEP to view the value of the RMEP ID field. Check whether the RMEP ID is displayed in the command output.

    • If the RMEP ID is displayed and the fault persists, go to Step 3.

    • If the RMEP ID is not displayed, go to Step 2.

  2. Perform the following steps on the MEP:
    1. Run the remote-mep mep-id mep-id [ mac mac-address ] command to specify a correct RMEP.
    2. Run the display alarm active command to view the trap. Check whether the trap is cleared. If the trap persists, go to Step 3.
  3. Collect alarm information and configuration information, and then contact technical support personnel.