ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail 132154
Description
ENTITYTRAP/2/BOARDFAIL: OID [oid] Board become failure for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=132154, EntityTrapReasonDescr="Voice Fault")
Some functions on the board are invalid.
Attribute
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.2.2.3 | Major | equipmentAlarm(5) |
Parameters
Name | Meaning |
---|---|
OID | Indicates the MIB object ID of the alarm. |
Index | Indicates the entity index. |
EntityPhysicalIndex | Indicates the physical entity index. |
PhysicalName | Indicates the name of the physical entity. |
EntityTrapEntType | Indicates the type of the physical entity, such as mpu(1), and lpu(2). |
EntityTrapFaultID | Indicates the error code. |
EntityTrapReasonDescr | Indicates the description of the error code. |
Procedure
- Check whether the faulty board is registered successfully and services are running properly.
Run the display device command to check whether the faulty board is registered successfully, and run the display interface counters command to view the statistics on received and sent packets. According to the statistics, check whether services are running properly.
- If the faulty board is registered successfully and services are running properly, no action is required.
- If the faulty board is unregistered or services are not running properly, go to step 2.
- If the faulty board is a main control board, run the reboot command to reboot the device. If the faulty board is an interface board,
run the reset slot command to reset the faulty interface board. Then check whether the device is working properly.
- If the board can be registered successfully and services are running properly, no action is required.
- If the board cannot be registered or services cannot run properly, the board hardware is faulty. Replace this board.
- If the fault persists, go to step 3.
- Collect alarm information and configuration information, and then contact technical support personnel.