Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.1.7 hwBoardReset

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.1.7 hwBoardReset

Description

ENTITYTRAP/3/BOARDRESET: OID [oid] The device has been reset.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", ResetInfo="[OCTET]")

The AC restarts.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.1.7 Minor equipmentAlarm(5)

Parameters

Name Meaning
OID

Indicates the MIB object ID of the alarm.

Index Indicates the index.
EntityPhysicalIndex Indicates a physical index.
PhysicalName Indicates an entity name, which varies with the board type, such as SFU, LPU, and MPU.
ResetInfo Indicates device restart information, including the restart reason and restart time.

Impact on the System

Service functions may be affected.

Possible Causes

  • Cause 1: The restart command is manually executed, and the device has been restarted normally.
  • Cause 2: The device has been restarted unexpectedly.

Procedure

  • Run the display reset-reason command to check device restart information.
    • If the information indicates a normal restart such as Reset by user command, the device has been restarted normally, and no action is required.
    • If the information contains exception, the device has been restarted unexpectedly. You need to collect the information and then contact technical support personnel.