Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFNET_1.3.6.1.4.1.2011.5.25.41.4.5 hwIfMonitorInputRateRising

IFNET_1.3.6.1.4.1.2011.5.25.41.4.5 hwIfMonitorInputRateRising

Description

IFNET/4/INBWRATEEXCEED: OID [oid] Interface input flow bandwidth usage exceeded the trap threshold. (Interface=[INTEGER], BandWidthUsage=[INTEGER], TrapThreshold=[INTEGER], InterfaceName=[STRING])

The trap was generated when the percentage of the rate of received traffic to the total bandwidth on an interface was greater than the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.4.5 Warning other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Interface

Indicates the interface index.

BandWidthUsage

Indicates bandwidth usage.

TrapThreshold

Indicates the trap threshold of bandwidth usage.

InterfaceName

Indicates the interface name.

Impact on the System

When the rate of traffic is close to 100% out of the total bandwidth, delay or packet loss will occur.

Possible Causes

The rate of traffic received by the interface was too large.

Procedure

  1. Run the display this interface command on the interface to check whether the traffic threshold is too low. The threshold range is specified by users according to actual services.

    • If so, go to Step 2.

    • If not, go to Step 3.

  2. Run the trap-threshold input-rate threshold_value command to reset the threshold and then check whether the alarm is cleared.

    • If so, go to Step 4.

    • If not, go to Step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.