Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NQA_1.3.6.1.4.1.2011.5.25.111.6.2 nqaResultsTestFailed

NQA_1.3.6.1.4.1.2011.5.25.111.6.2 nqaResultsTestFailed

Description

NQA/4/TESTFAIL:OID [oid] NQA entry test failed. (OwnerIndex=[OCTET], TestName=[OCTET])

Indicates that the number of continuous testing failures in a test instance reached the set threshold. The value of the default threshold was 1, that is, a trap was generated right after each test failure. The test-failtimes command can modify the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.111.6.2 Warning processingErrorAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

OwnerIndex

Indicates the administrator of an NQA test instance.

TestName

Indicates the name of an NQA test instance.

Impact on the System

None.

Possible Causes

This trap occurs in the NQA test.

1.

The destination address was inexistent and unreachable.

2.

The destination address existed, but the route was unreachable.

3.

Because of the network latency, the RTT of the Trace packet was longer than the set timeout period.

Procedure

  1. Run the display this command in the NQA test view to check whether the destination address is correctly configured. If not, run the destination-address command in the NQA test view to modify the destination address.

    Perform the test again to check whether the alarm is cleared.
    • If so, go to Step 5.
    • If not, go to Step 2.

  2. Run the ping command in the NQA test view to check whether the route is reachable.

    • If the destination address is correctly configured, but the route is not reachable, run the display ip routing-table command to check and routing table and rectify the routing fault. If the test fails again, go to Step 4.
    • If the route is reachable, go to Step 3.

  3. Run the timeout command in the NQA test view to modify the timeout period according to the status of the current network. It is recommended that you modify the timeout period to the default value, that is, three seconds. The value of the timeout period ranges from 1 second to 60 seconds. You can run the display this command in the NQA test view to see the current timeout period.

    Perform the test again to check whether the alarm is cleared.
    • If so, go to Step 5.
    • If not, go to Step 4.

  4. Collect alarm information and configuration information, and then contact technical support personnel.
  5. End.