Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IPFPM_1.3.6.1.4.1.2011.5.25.316.3.8 hwIpfpmTlpExceed

IPFPM_1.3.6.1.4.1.2011.5.25.316.3.8 hwIpfpmTlpExceed

Description

IPFPM/2/TLP_EXCEED:OID [oid] The number of board tlp exceeded the threshold. (BoardIndex=[BoardIndex], BoardTlpNumber=[BoardTlpNumber], ThresholdValue=[ThresholdValue])

The number of TLPs configured on a board exceeded the TLP threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.316.3.8

Major

qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

BoardIndex

Board index

BoardTlpNumber

Number of TLPs configured on a board

ThresholdValue

Number of TLPs allowed by a board

Impact on the System

The number of TLPs configured on a board exceeded the TLP threshold of the board, consuming more board resources. Therefore, the board processing performance is affected.

Possible Causes

The number of TLPs configured on a board exceeded the TLP threshold of the board.

Procedure

  1. Check whether the TLPs on a board are normally configured.

    • If so, go to Step 2.
    • If not, go to Step 3.

  2. Check whether the normally configured TLPs are referenced by services in the DCP view.

    • If so, go to Step 5.
    • If not, go to Step 4.

  3. Delete the TLPs that are incorrectly configured and check whether the trap persists.

    • If so, go to Step 2.
    • If not, go to Step 6.

  4. Delete TLPs that are not referenced by services. Run the display ipfpm dcp command to check the maximum number of TLPs that the board supports. Ensure that the number of TLPs configured on the board is smaller than the maximum number of TLPs that the board supports and check whether the trap persists.

    • If so, go to Step 5.
    • If not, go to Step 6.

  5. Collect alarm information and configuration information, and then contact technical support personnel.
  6. End.