Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MGMD_1.3.6.1.4.1.2011.5.25.149.3.3.19 hwMgmdHostSGThresholdExceedClear

MGMD_1.3.6.1.4.1.2011.5.25.149.3.3.19 hwMgmdHostSGThresholdExceedClear

Description

MGMD/3/hwMgmdHostSGThresholdExceedClear:OID [oid] IGMP or MLD total (S, G) entries on the host side of all instances count fell below the lower threshold. (hwMgmdNotificationAddressType=[integer], hwMgmdHostSGCurrentCount=[integer], hwMgmdHostSGThreshold=[integer]%, hwMgmdHostSGTotalCount=[integer])

The (S, G) entry usage of all instances fell below the specified lower alarm threshold on the user-side IGMP/MLD device.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.149.3.3.19

Minor

communicationsAlarm

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwMgmdNotificationAddressType

Group address type:
  • 1: IPv4 address

  • 2: IPv6 address

hwMgmdHostSGCurrentCount

Number of existing (S, G) entries of all instances on the user-side IGMP/MLD device

hwMgmdHostSGThreshold

Upper and lower alarm thresholds for the (S, G) entry usage of all instances on the user-side IGMP/MLD device

hwMgmdHostSGTotalCount

Maximum limit of total number of (S, G) entries of all instances on the user-side IGMP/MLD device

Impact on the System

Services will not be affected.

Possible Causes

The (S, G) entry usage of all instances fell below the specified lower alarm threshold on the user-side IGMP/MLD device.

Procedure

  1. This message is informational only, and no action is required.

Related Information

None