Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LACP_1.3.6.1.4.1.2011.5.25.41.3.34 hwLacpPartnerExpiredLoss

LACP_1.3.6.1.4.1.2011.5.25.41.3.34 hwLacpPartnerExpiredLoss

Description

LACP/2/PEL:OID [oid] The member of LAG receive expired PDU from partner. (TrunkIndex=[INTEGER], PortIfIndex=[INTEGER], TrunkId=[INTEGER], TrunkName=[OCTET], PortName=[OCTET])

The local end received a timeout packet from the remote end.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.3.34 Major other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

TrunkIndex

Index of an Eth-Trunk interface in static LAC mode

PortIfIndex

Index of an Eth-Trunk member interface in static LAC mode

TrunkId

ID of an Eth-Trunk interface in static LAC mode

TrunkName

Name of an Eth-Trunk interface in static LAC mode

PortName

Name of an Eth-Trunk member interface in static LAC mode

Impact on the System

Partial or all link bandwidth will lose, causing partial or all services to be interrupted.

Possible Causes

The remote end could not receive the LACP packet from the local end.

Procedure

  • If both local and remote ends are Huawei Datacom devices, the handling procedures are as follows.
    1. Check whether the interface is Down.

      • If so, go to Step 2.

      • If not, go to Step 4.

    2. Run the undo shutdown command to check whether the alarm is cleared.

      • If the alarm is cleared, go to Step 8.

      • If the alarm is not cleared, go to Step 3.

    3. Check whether the physical link is faulty.

      • If so, go to Step 6.

      • If not, go to Step 4.

    4. Check whether there is an interface on the local or remote end of the link leaving the LAG.

      • If so, go to Step 5.

      • If not, go to Step 7.

    5. Check whether the interface leaves the LAG normally.

      • If so, go to Step 8.

      • If not, go to Step 7.

    6. Repair the physical link and then check whether the alarm is cleared.

      • If the alarm is cleared, go to Step 8.

      • If the alarm is not cleared, go to Step 4.

    7. Collect alarm information and configuration information, and then contact technical support personnel.
    8. End.
  • If the local end is a Huawei Datacom device, but the remote end is a non-Huawei Datacom device, contact technical personnel from the device's manufacturer.