Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FIB_1.3.6.1.4.1.2011.5.25.227.2.1.15 hwBoardFwdResThresholdExceed

FIB_1.3.6.1.4.1.2011.5.25.227.2.1.15 hwBoardFwdResThresholdExceed

Description

FIB/4/BOARD_FWD_RES_THRESHOLD_EXCEED:OID [oid] The board forwarding engine resources exceeded the threshold. (EntPhysicalindex=[INTEGER], EntPhysicalName=[OCTET], Reason=[INTEGER])

The board forwarding engine resources exceeded the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.227.2.1.15 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

EntPhysicalindex

Index of the physical entry

EntPhysicalName

Name of the physical entry

Reason

The probable cause of trap, which can only be:
  • 99: The threshold value of forward tokens on the board.

Impact on the System

The board forwarding engine resources reached the threshold value. Services will be affected if the number of forward tokens keeps increasing.

Possible Causes

Cause 99:

The percentage of tokens in the board space exceeded 80% of the upper threshold supported by the forwarding engine.

Procedure

  1. Run the display mpls lsp statistics command to check whether the number of created tunnels exceeds the expected number and whether the number of tokens on the device exceeds the upper threshold.

    • If the number of created tunnels exceeds the expected number, remove the redundant tunnels. If the alarm persists, go to Step 2.

    • If the number of created tunnels does not exceed the expected number, go to Step 2.

  2. Collect alarm information and configuration information, and then contact technical support personnel.