Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FIB_1.3.6.1.4.1.2011.5.25.227.2.1.14 hwWholeFwdResThresholdExceedResume

FIB_1.3.6.1.4.1.2011.5.25.227.2.1.14 hwWholeFwdResThresholdExceedResume

Description

FIB/4/WHOLE_FWD_RES_THRESHOLD_EXCEED_RESUME:OID [oid] The whole device forwarding engine resources fell from the threshold. (EntPhysicalindex=[INTEGER], EntPhysicalName=[OCTET], Reason=[INTEGER])

The whole device forwarding engine resources fell from the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.227.2.1.14 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

EntPhysicalindex

The index of physical entry.

EntPhysicalName

The name of physical entry.

Reason

The probable cause of trap:
  • 98: The threshold value of forward tokens in Global 1 space.
  • 100: The threshold value of forward tokens in Global 2 space.
  • 101: The threshold value of forward tokens in Global 3 space.
  • 102: The threshold value of forward tokens in Global 4 space.

Impact on the System

None

Possible Causes

After the whole device forwarding engine resources fell below the threshold, if some services are deleted and the forward resource requirement can be satisfied, the elimination of the alarm will be reported.

Procedure

  1. This trap message is informational only, and no action is required.