Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BFD_1.3.6.1.4.1.2011.5.25.38.3.3 hwBfdSessReachLimit

BFD_1.3.6.1.4.1.2011.5.25.38.3.3 hwBfdSessReachLimit

Description

BFD/4/BFD_SESSLMT_TRAP:OID [oid] The session number in all the IO boards has reached the limit, the new session can not be created. (TotalSessionLimit=[integer])

The trap was generated when the number of all the BFD sessions set up on interface boards reached the PAF upper limit and no more session can be set up. You can run the display bfd statistics command to view information about BFD_SESSION_NUM and know the upper limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.38.3.3 Warning qualityOfServiceAlarm (3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

TotalSessionLimit

Indicates the upper limit of global BFD sessions.

Impact on the System

Services will not be affected.

Possible Causes

New BFD configurations were still committed when the number of global BFD sessions reached the upper limit

Procedure

  1. Run the display bfd statistics command to check whether the number of BFD sessions displayed below the PAF/LCS Name field has reached the upper limit.

    • If so, go to Step 2.
    • If not, go to Step 3.

  2. Run the undo bfd session-name command to delete useless BFD sessions. The configurations of committed BFD sessions are automatically created. In this case, go to Step 4.
  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.

Related Information

None