Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136202

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136202

Description

ENTITYTRAP/4/OPTICALINVALID:OID [oid] Optical module is invalid.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=136202, EntityTrapReasonDescr="Optical Temperature Too Low")

The temperature of the optical module is below the lower limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.4.5 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid

Indicates the MIB object ID of the alarm.

Index Indicates the index of the alarm.
EntityPhysicalIndex Indicates the entity index.
PhysicalName Indicates the name of the physical entity.
EntityTrapFaultID Indicates the error code of the alarm.
EntityTrapReasonDescr Indicates the description of the error code.

Impact on the System

Services are interrupted on the interface with the optical module installed.

Possible Causes

The temperature of the optical module is below the lower limit.

Procedure

  1. Run the display transceiver verbose command in user view to check temperature of the optical module.
  2. If temperature of the optical module is below the lower limit, adjust the air conditioning system in the equipment room to raise the temperature.
  3. If the alarm persists, collect alarm information, log information, and configuration of the device and contact technical support personnel.