Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm

Description

ENTITYTRAP/1/ENTITYBRDTEMPALARM:OID [OID] Temperature rise over or fall below the warning alarm threshold.(Index=[INTEGER1],EntryPhysicalIndex=[INTEGER2], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER3],EntityThresholdValue=[INTEGER4],EntityThresholdCurrent=[INTEGER5], EntityTrapFaultID=[INTEGER6])

This alarm is generated when the temperature is not within the threshold. You can run the display temperature command to view the alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.10.13 Critical environmentalAlarm (6)

Parameters

Name Meaning
OID

Indicates the MIB object ID of the alarm.

Index Indicates the index of a temperature sensor.
EntryPhysicalIndex Indicates the sub-index of an entity.
PhysicalName Indicates the name of an entity.
EntityThresholdType
Indicates the alarm type.
  • 1: rise over
  • 2: fall below
EntityThresholdValue Indicates the alarm threshold.
EntityThresholdCurrent Indicates the current temperature.
EntityTrapFaultID Indicates the cause ID of the alarm.

Impact on the System

The board overheats. If the temperature is higher than the fatal high temperature threshold, the board will be powered off, leading to service interruption.

Possible Causes

The fan is faulty, causing high temperature of the board.

Procedure

  1. Run the display temperature all command to check the device temperature.
  2. Run the display fan command to check the fan status and speed. Cool the device quickly. If a fan alarm is displayed at the same time, replace the fan.