Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.1 hwBoardRemove

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.1 hwBoardRemove

Description

ENTITYTRAP/4/BOARDREMOVE: OID [oid] Board has been removed.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER])

A board was removed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.2.1 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID

Indicates the MIB object ID of the alarm.

Index Indicates the index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the physical entity name.
EntityTrapEntType Indicates the entity type, such as mpu(1) and lpu(2).
EntityTrapFaultID Indicates the error code.

Impact on the System

All services on the board are interrupted.

Possible Causes

A board was removed.

Procedure

  1. Check whether the board was removed manually.

    • If so, no action is required.
    • If not, go to step 2.

  2. Insert the corresponding board. After the board is started, run the display device command to check whether the board in the corresponding slot is registered successfully.

    • If not, go to step 4.
    • If so, go to step 3.

  3. End.
  4. Collect alarm information and configuration information, and then contact technical support personnel.