No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.21.1hwRpsPowerRemove

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.21.1hwRpsPowerRemove

Description

ENTITYTRAP/4/RPSPOWERREMOVE: OID [oid] RPS Power has been removed.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER],PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])

The RPS power supply has been removed.

NOTE:

Only the AR2201-48FE-S, AR2204-S, and AR2204-27GE-S support alarms about the RPS power supply.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.219.2.21.1

Warning equipmentAlarm (5)

Parameters

Name Meaning
OID

Indicates the MIB object ID of the alarm.

Index Indicates the entity index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the physical entity name.
EntityTrapFaultID Indicates the error code.

Impact on the System

This alarm does not affect the system if the internal power modules of the device are working properly. If the internal power modules of the device cannot work properly, all services on the device are interrupted.

Possible Causes

Cause 1:

The RPS power supply has been removed.

Cause 2:

The RPS power supply is powered off.

Cause 3:

The RPS interface on the device is faulty.

Procedure

  1. Run the display rps status command to check whether the RPS power supply is present. If not, check whether the cable connected to the RPS power supply is removed or loose. Properly connect the RPS cable. If the fault persists, contact technical support personnel.
Translation