Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM_Y1731_1.3.6.1.4.1.2011.5.25.136.1.6.53 hwY1731StatisticClear

EOAM_Y1731_1.3.6.1.4.1.2011.5.25.136.1.6.53 hwY1731StatisticClear

Description

EOAM_Y1731/4/STATISTICCLEAR: OID [OID] The Y.1731 statistic value fell below the lower limit value. (MdIndex=[INTEGER], MaIndex=[INTEGER], MepID=[INTEGER], Type=[INTEGER], MAC=[OPAQUE], Priority=[INTEGER], MdName=[STRING], MaName=[STRING], Value=[INTEGER], UpperLimitThreshold=[INTEGER], LowerLimitThreshold=[INTEGER])

The Y.1731 performance statistic value fell below the alarm clear threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.136.1.6.53 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

MdIndex

Index of an MD table

MaIndex

Index of an MA table

MepID

MEP ID

Type

Alarm type

MAC

MAC address

Priority

Priority of performance measurement

MdName

Name of an MD

MaName

Name of an MA

Value

Y.1731 performance statistic value

UpperLimitThreshold

Upper threshold

LowerLimitThreshold

Lower threshold

Impact on the System

Services are not affected.

Possible Causes

The Y.1731 performance statistic value fell below the alarm clear threshold.

Procedure

  1. This alarm is informational only, and no action is required.