No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NQA_1.3.6.1.2.1.80.0.2 pingTestFailed

NQA_1.3.6.1.2.1.80.0.2 pingTestFailed

Description

NQA/4/PINGFAIL:OID [oid] Ping entry test failed. (Admin=[OCTET], Tag=[OCTET])

The trap was generated when the number of continuous test failures reached the threshold. The default threshold was 1. You can run the test-failtimes command to modify the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.2.1.80.0.2 Warning communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Admin

Indicates the index of the test administrator.

Tag

Indicates the index of the test name.

Impact on the System

None.

Possible Causes

This trap occurred in the NQA test.

1.

The destination address was inexistent and the route was unreachable.

2.

The destination address existed, but the route was unreachable.

3.

Because of the network delay, the RTT of the packet was longer than the set timeout period.

Procedure

  1. Run the display this command in the NQA test view to check whether the destination address is correctly configured. If not, run the destination-address command in the NQA test view to modify the destination address.

    Perform the test again to check whether the alarm is cleared.
    • If so, go to Step 5.
    • If not, go to Step 2.

  2. Run the ping command in the NQA test view to check whether the route is reachable.

    • If the destination address is correctly configured, but the route is not reachable, run the display ip routing-table command to check the routing table and rectify the routing fault. If the test fails again, go to Step 4.
    • If the route is reachable, go to Step 3.

  3. Run the timeout command in the NQA test view to modify the timeout period according to the status of the current network. It is recommended that you modify the timeout period to the default value, that is, three seconds. The value of the timeout period ranges from 1 second to 60 seconds. You can run the display this command in the NQA test view to view the current timeout period.

    Perform the test again to check whether the alarm is cleared.
    • If so, go to Step 5.
    • If not, go to Step 4.

  4. Collect alarm information and configuration information, and then contact technical support personnel.
  5. End.

Related Information

None

Translation
Download
Updated: 2019-05-06

Document ID: EDOC1000174085

Views: 120514

Downloads: 20

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next