Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PDINVALIDCLASS

PDINVALIDCLASS

Description

HUAWEI POE/PDINVALIDCLASS: Get PD classification failed.(PortIndex=[integer])

The PD did not comply with 802.3af or 802.3at standards and failed to be classified and powered on.

Attribute

Alarm ID Alarm Severity Alarm Type
None None None

Parameters

Name Meaning
PortIndex Indicates the port number.

Impact on the System

The PD cannot be powered on.

Possible Causes

The PD did not comply with 802.3af or 802.3at standards.

Procedure

  • Replace the PD with a 802.3af or 802.3at-compliant PD.
  • Run the poe legacy enable port port-num command to enable compatibility check so that a PoE midspan can detect and provide power for the PDs incompliant with 802.3af or 802.3at.

    NOTE:

    It is not recommended to provide power for the PDs incompliant with 802.3af or 802.3at.