Alarm Handling

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L2V_1.3.6.1.4.1.2011.5.25.119.1.2.7 hwVplsVcDeleted

L2V_1.3.6.1.4.1.2011.5.25.119.1.2.7 hwVplsVcDeleted

Description

L2V/4/VPLSVC_DEL_T:OID [oid] The VPLS VC has been deleted. (VsiName=[STRING], PwId=[GAUGE], RemoteIp=[IPADDR], PwType=[INTEGER])

The VPLS VC was deleted.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.119.1.2.7

Warning

qualityOfServiceAlarm (3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

VsiName

Name of the VSI

PwId

ID of the PW

RemoteIp

IP address of the remote peer

PwType

Type of the PW. The values are as follows:
  1. normal
  2. other

Impact on the System

If the VPLS VC is Up, services on it are interrupted.

Possible Causes

Cause 1:

The peer was deleted in the VSI view, or the VSI was manually deleted.

Cause 2:

L2VPN or MPLS was disabled.

Procedure

  1. This alarm is informational only, and no action is required.
Translation