Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxBeforeRouteChgTable

hwEntPbxBeforeRouteChgTable

This table describes configurations of pre-routing number change. You can configure number change rules to implement the user number change service.

The index of this table is hwEntPbxBeforeRouteChgName.

The table entry of this table is hwEntPbxBeforeRouteChgEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.313.17.1.1

hwEntPbxBeforeRouteChgName

OCTET STRING

This object indicates the pre-routing number change plan name.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.4.1.2011.5.25.313.17.1.2

hwEntPbxBeforeRouteChgRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.3

hwEntPbxBeforeRouteChgCallprefixName

OCTETSTRING

This object indicates the name of a call prefix.

Length: a string of 1 to 32 digits

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.4

hwEntPbxBeforeRouteChgCountryCode

OCTET STRING

This object indicates the country or region code.

Length: a string of 1 to 4 digits

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.5

hwEntPbxBeforeRouteChgAreaCode

OCTET STRING

This object indicates the area code.

Length: a string of 1 to 8 digits

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.6

hwEntPbxBeforeRouteChgCallerNum

OCTET STRING

This object indicates the calling number.

Length: a string of 1 to 24 digits

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.7

hwEntPbxBeforeRouteChgCentrexNumber

OCTET STRING

This object indicates the number in a Centrex group.

Length: a string of 1 to 8 digits

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.8

hwEntPbxBeforeRouteChgOrigDNChgType

INTEGER

This object indicates the change type of the calling number.

The options are as follows:

  • l1:noChange
  • l2:modify
  • l3:delete
  • l4:insert

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.9

hwEntPbxBeforeRouteChgOrigDNChgPos

Integer32

This object indicates the changed position of the calling number.

The value is an integer ranging from 1 to 44.

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.10

hwEntPbxBeforeRouteChgOrigDNChgLen

Integer32

This object indicates the changed length of the calling number.

The value is an integer ranging from 1 to 44.

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.11

hwEntPbxBeforeRouteChgOrigDNNew

OCTET STRING

This object indicates the new calling number.

Length: a string of 1 to 24 digits

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.12

hwEntPbxBeforeRouteChgTermDNChgType

INTEGER

This object indicates the change type of the called number.

The options are as follows:

  • 1: noChange
  • 2: modify
  • 3: delete
  • 4: insert

Default value: noChange

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.13

hwEntPbxBeforeRouteChgTermDNChgPos

Integer32

This object indicates the changed position of the called number.

The value is an integer ranging from 1 to 44.

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.14

hwEntPbxBeforeRouteChgTermDNChgLen

Integer32

This object indicates the changed length of the called number.

The value is an integer ranging from 1 to 44.

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.15

hwEntPbxBeforeRouteChgTermDNNew

OCTET STRING

This object indicates the new called number.

Length: a string of 1 to 24 digits

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.16

hwEntPbxBeforeRouteChgReAnalyse

INTEGER

This object indicates whether to reanalyze the new number.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.17

hwEntPbxBeforeRouteChgDualDialToneFlag

INTEGER

This object indicates whether to play the two-stage dialing tone.

The options are as follows:

  • 1: disable
  • 2: enable

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.18

hwEntPbxBeforeRouteChgNewEnterprise

OCTET STRING

This object indicates the new enterprise name.

Length: a string of 0 to 32 characters

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.19

hwEntPbxBeforeRouteChgNewDnSet

OCTET STRING

This object indicates the new DN set.

Length: a string of 1 to 32 characters

read-create

current

1.3.6.1.4.1.2011.5.25.313.17.1.20

hwEntPbxBeforeRouteChgNewCentrex

This object indicates the new Centrex group ID.

This object indicates the new Centrex group ID.

Length: a string of 1 to 32 digits

read-create

current

Creation Restriction

To create an entry, set values for hwEntPbxBeforeRouteChgOrigDNChgType, hwEntPbxBeforeRouteChgTermDNChgType, and hwEntPbxBeforeRouteChgCallprefixName.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 511526

Downloads: 49

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next