Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwTwampSenderAdminTable

hwTwampSenderAdminTable

This table is used to start test sessions.

The index of this table is hwTwampSenderId.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.333.1.1.4.1.1

hwTwampSenderAdminContinual

INTEGER{true(1),false(2)}

Read-create

The value of this object identifies a test session for proactive or on-demand measurement.
NOTE:
  • To start a test session for proactive measurement, do not configure hwTwampSenderAdminDuration or hwTwampSenderAdminPacketCount.
  • To start a test session for on-demand measurement, configure either hwTwampSenderAdminDuration or hwTwampSenderAdminPacketCount.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.4.1.2

hwTwampSenderAdminDuration

Integer32 (SIZE (0..0)) (SIZE (60..300))

Read-create

The value of this object identifies a period during which on-demand measurement is implemented.

NOTE:
  • 0 indicates that the object is not configured.
  • If on-demand measurement mode is configured, hwTwampSenderAdminDuration or hwTwampSenderAdminPacketCountStart must be set. If hwTwampSenderAdminDuration and hwTwampSenderAdminPacketCountStart are both set, their values cannot all be 0.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.4.1.3

hwTwampSenderAdminPacketCount

Integer32 (SIZE (0..0)) (SIZE (100..30000))

Read-create

The value of this object identifies the number of packets that can be sent for on-demand measurement.

NOTE:
  • 0 indicates that the object is not configured.
  • If on-demand measurement mode is configured, hwTwampSenderAdminDuration or hwTwampSenderAdminPacketCountStart must be set. If hwTwampSenderAdminDuration and hwTwampSenderAdminPacketCountStart are both set, their values cannot all be 0.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.4.1.4

hwTwampSenderAdminPeriod

INTEGER{interval10ms(1),interval100ms(2),interval1s(3),interval30s(4)}

Read-create

The value of this object identifies the interval at which on-demand measurement is implemented.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.4.1.5

hwTwampSenderAdminTimeOut

Integer32 (SIZE (1..10))

Read-create

The value of this object identifies the timeout period for response packets.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.4.1.99

hwTwampSenderAdminRowStatus

RowStatus

Read-create

This object indicates the row status of this entry.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

  • To start a test session for proactive measurement, do not configure hwTwampSenderAdminDuration or hwTwampSenderAdminPacketCount.
  • To start a test session for on-demand measurement, configure either hwTwampSenderAdminDuration or hwTwampSenderAdminPacketCount.

Modification Restriction

  • The entries for proactive measurement cannot be modified.
  • The entries for on-demand measurement can be modified. You can also change the attribute of a test session from on-demand measurement to proactive measurement.

Deletion Restriction

The entries in this table can be deleted.

Access Restriction