Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxAt0TrkTable

hwEntPbxAt0TrkTable

This table is used to configure and maintain AT0 trunks.

The index of this table is hwEntPbxAt0TrkIndex.

The table entry of this table is hwEntPbxAt0TrkEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.313.13.1.1

hwEntPbxAt0TrkIndex

INTEGER32

This object indicates the index of the AT0 trunk and maps the slot ID, subcard ID, and port number. When the slot ID, subcard ID, and port number are converted into a 32-bit binary number:

  • 0-7: port index
  • 8-15: subcard index
  • 16-23: slot index
  • 24-31: reserved

The value is an integer in decimal notation. It can be expressed in the format of slot ID/subcard ID/port number. For example, in 1/0/2, 1 indicates the slot ID; 0 indicates the subcard ID, and 2 indicates the port number. If it is expressed in the 32-bit binary number, 1/0/2 is expressed as 000000000 00000001 00000000 00000010. The first eight digits 000000000 is reserved. The second eight digits 00000001 indicates slot ID 1. The third eight digits 000000000 indicates subcard ID 0. The fourth eight digits 00000010 indicates port number 2. The index of 1/0/2 is 65538.

not-accessible

current

1.3.6.1.4.1.2011.5.25.313.13.1.2

hwEntPbxAt0TrkRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.4.1.2011.5.25.313.13.1.3

hwEntPbxAt0TrkPhyStatus

INTEGER

This object indicates the physical status of the AT0 trunk circuit.

The options are as follows:

  • 1: block
  • 2: normal

Default value: normal

read-only

current

1.3.6.1.4.1.2011.5.25.313.13.1.4

hwEntPbxAt0TrkSrvState

INTEGER

This object indicates the service status of the AT0 trunk circuit.

The options are as follows:

  • 1: idle
  • 2: busy
  • 3: fault
  • 4: block

read-only

current

1.3.6.1.4.1.2011.5.25.313.13.1.5

hwEntPbxAt0TrkGroupName

INTEGER

This object indicates the name of a trunk group.

Length: a string of 1 to 32 characters

read-write

current

1.3.6.1.4.1.2011.5.25.313.13.1.6

hwEntPbxAt0TrkDialDelay

Integer32

This object indicates the dial delay time.

Value range: 0 to 20000

Unit: millisecond

Default value: 2000

read-write

current

1.3.6.1.4.1.2011.5.25.313.13.1.7

hwEntPbxAt0TrkInsertPrefix

OCTET STRING

This object indicates the inserted prefix.

Length: a string of 1 to 4 digits

read-write

current

1.3.6.1.4.1.2011.5.25.313.13.1.8

hwEntPbxAt0TrkInsertDelay

Integer32

This object indicates the dial delay time after the prefix is inserted.

Value range: 0 to 20000

Unit: millisecond

Default value: 2000

read-write

current

1.3.6.1.4.1.2011.5.25.313.13.1.9

hwEntPbxAt0ReversePole

INTEGER

This object indicates whether the peer device of the AT0 trunk supports polarity reversal.

The options are as follows:

  • 1: disable
  • 2: enable

Default value: enable

read-write

current

1.3.6.1.4.1.2011.5.25.313.13.1.10

hwEntPbxAt0TrkDefaultCalledNum

OCTET STRING

This object indicates the default called number.

Length: a string of 1 to 32 digits

read-write

current

1.3.6.1.4.1.2011.5.25.313.13.1.11

hwEntPbxAt0TrkCidTransType

INTEGER

This object indicates the signal transmission type for the calling line identification presentation (CLIP) service.

The options are as follows:

  • 1: bell202
  • 2: v23
  • 3: ntt
  • 4: dtmf
  • 5: r15
  • 6: bell202V23Dtmf
  • 7: none

Default value: bell202

read-write

current

1.3.6.1.4.1.2011.5.25.313.13.1.12

hwEntPbxAt0PTPDialMode

INTEGER

This object indicates a dialing mode.

The options are as follows:

  • 1: dtmf
  • 2: pulse

Default value: dtmf

read-write

current

Creation Restriction

To create an entry, set values for hwEntPbxAt0TrkGroupName and hwEntPbxAt0TrkDefaultCalledNum.

Modification Restriction

The object hwEntPbxAt0TrkGroupName cannot be modified.

Deletion Restriction

  • The entries in the table cannot be deleted when the trunk is busy.
  • You must set a value for hwEntPbxAt0TrkGroupName before deleting the entries.

Access Restriction

None.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 481506

Downloads: 48

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next