No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwDot3ahEfmLoopbackTable

hwDot3ahEfmLoopbackTable

This table is used to control the loopback on interfaces.

The index of this table is ifIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.136.1.2.2.4.1.1

hwDot3ahEfmLoopbackStatus

INTEGER

{

noLoopback(1),

initiatingLoopback(2),

remoteLoopback(3),

terminatingLoopback(4),

localLoopback(5),

unknown(6)

}

Read-write

This object indicates that the index is the interface number.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.4.1.2

hwDot3ahEfmLoopbackIgnoreRx

INTEGER

{

ignore(1),

process(2)

}

read-write

Indicates the way to handle the request.
  • ignore(1): ignore the request.

  • process(2): handle the request.

The default is process.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.4.1.3

hwDot3ahEfmLoopbackTimeout

Unsigned32 (0..1000)

read-write

The interval for remote loopback.

The default is 20 minutes.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

EFM must be enabled globally first.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 512463

Downloads: 49

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next