Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPstnUserConfigTable

hwEntPstnUserConfigTable

This table is used to add, modify, delete, and query PSTN users.

The index of this table is hwEntPraUserName.

The table entry of this table is hwEntPstnUserConfigEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.251.1.1.1

hwEntPstnUserName

OCTET STRING

This object indicates a user name.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.4.1.2011.5.25.251.1.1.2

hwEntPstnUserPort

Integer32

This object indicates a user port number.

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.3

hwEntPstnUserMgId

Integer32

This object indicates the SIP AG interface ID.

Value range: 0 to 16777215

This object does not have a default value.

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.4

hwEntPstnUserTelNo

OCTET STRING

This object indicates a user's phone number.

Length: a string of 0 to 32 digits

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.5

hwEntPstnUserUserGroupId

OCTET STRING

This object indicates a user group name.

Length: a string of 0 to 32 characters

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.6

hwEntPstnUserRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

At present, only createAndGo and destroy are supported.

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.7

hwEntPstnUserPriority

INTEGER

This object indicates a user priority.

The options are as follows:

  • 1: cat1
  • 2: cat2
  • 3: cat3

Default value: cat3

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.8

hwEntPstnUserPotsLineType

INTEGER

This object indicates the POTS line type.

The options are as follows:

  • 1: del
  • 2: lcPBX
  • 3: ecPBX
  • 4: payPhone

Default value: del

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.9

hwEntPstnUserDCTime

Integer32

This object indicates the power-off interval.

Value range: 0 to 100

Default value: 10

The value is expressed in 10 ms.

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.10

hwEntPstnUserFSKDelayInterval

Integer32

This object indicates the FSK delay interval.

Value range: 0 to 100

Default value: 80

The value is expressed in 10 ms.

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.11

hwEntPstnUserCidTransSequence

INTEGER

This object indicates when a calling number is delivered.

The options are as follows:

  • 1: afterRing
  • 2: beforeRing

Default value: afterRing

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.12

hwEntPstnUserCidFormat

INTEGER

This object indicates the calling number format.

The options are as follows:

  • 1: sdmfFsk
  • 2: mdmfFsk
  • 3: dtmf
  • 4: r15
  • 5: etsi

Default value: sdmfFsk

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.13

hwEntPstnUserVQEAgc

INTEGER

This object indicates whether to enable the automatic gain control (AGC) function.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.14

hwEntPstnUserVQESns

INTEGER

This object indicates whether to enable the spectral noise suppression (SNS) function.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.15

hwEntPstnUserVQEAgcLevel

Integer32

This object indicates the AGC destination value.

Value range: 0 to 15

Default value: 13

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.16

hwEntPstnUserVQESnsLevel

Integer32

This object indicates the SNS suppression level.

Value range: 6 to 20

Default value: 12

Unit: dB

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.17

hwEntPstnUserDspInputGain

Integer32

This object indicates the DSP receiving gain.

The options are as follows:

0: -10 dB

1: -9 dB

2: -8 dB

3: -7 dB

4: -6 dB

5: -5 dB

6: -4 dB

7: -3 dB

8: -2 dB

9: -1 dB

10: 0 dB

11: 1 dB

12: 2 dB

13: 3 dB

14: 4 dB

15: 5 dB

Default value: 10 (0 dB)

Unit: dB

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.18

hwEntPstnUserDspOutputGain

Integer32

This object indicates the DSP sending gain.

The options are as follows:

0: -10 dB

1: -9 dB

2: -8 dB

3: -7 dB

4: -6 dB

5: -5 dB

6: -4 dB

7: -3 dB

8: -2 dB

9: -1 dB

10: 0 dB

11: 1 dB

12: 2 dB

13: 3 dB

14: 4 dB

15: 5 dB

16: 6 dB

17: 7 dB

18: 8 dB

19: 9 dB

20: 10 dB

Default value: 10 (0 dB)

Unit: dB

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.19

hwEntPstnUserDetectANSbarBySingleTone

INTEGER

This object indicates whether to detect ANSbar signals by sending a single tone.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.20

hwEntPstnUserBellANS

INTEGER

This object indicates whether to enable Bell ANS.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.21

hwEntPstnUserDspParaTemplate

OCTET STRING

This object indicates the name of a DSP parameter template.

Length: a string of 0 to 31 characters

This object does not have a default value.

NOTE:

If the DSP template name issued by the NMS does not exist, the host will return an error code indicating that the DSP template name does not exist.

The DSP parameter template is mainly used for the data service and is available only when the automatic negotiation mode is used for fax/modem. If the template is used when the softswitch uses the negotiation mode, certain functions may be unavailable.

If this object is not specified, a null string is obtained after the execution of the GET command.

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.22

hwEntPstnUserCidFskMode

INTEGER

This object indicates the FSK mode for the display of calling numbers.

The options are as follows:

  • 1: bell202
  • 2: ccittV23
  • 3: ntt

Default value: bell_202

read-create

current

1.3.6.1.4.1.2011.5.25.251.1.1.23

hwEntPstnUserCidTasPattern

INTEGER

This object indicates the TAS mode for the display of calling numbers.

The options are as follows:

  • 1: noTas
  • 2: dtAs

Default value: noTas

read-create

current

Creation Restriction

When configuring an entry, you must configure the user port number and interface ID at the same time.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation