Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntRedundancyTable

hwEntRedundancyTable

This table is used to configure and query the redundancy transmission parameters of the SIP AG interfaces.

The index of this table is hwEntRedundancySipAgId.

The table entry of this table is hwEntRedundancyEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.250.15.1.1

hwEntRedundancySipAgId

Integer32

This object indicates the ID of a SIP AG interface.

Value range: 0 to 16777215

Not-accessible

Current

1.3.6.1.4.1.2011.5.25.250.15.1.2

hwEntRedundancyNegoMode

INTEGER

This object indicates the negotiation startup mode for redundancy transmission.

The options are as follows:

  • 1: negoStart
  • 2: fixedStart
  • 3: noInitiativeStart

Default value: noInitiativeStart

Read-write

Current

1.3.6.1.4.1.2011.5.25.250.15.1.3

hwEntRedundancyStartMode

INTEGER

This object indicates the startup mode for redundancy transmission.

The options are as follows:

  • 1: smartRedundancy
  • 2: ordinaryRedundancy

Default value: ordinaryRedundancy

Read-write

Current

1.3.6.1.4.1.2011.5.25.250.15.1.4

hwEntRedundancyNte

INTEGER

This object indicates whether to enable NTE for redundancy transmission.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

Read-write

Current

1.3.6.1.4.1.2011.5.25.250.15.1.5

hwEntRedundancyVbd

INTEGER

This object indicates whether to enable VBD for redundancy transmission.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: enable

Read-write

Current

1.3.6.1.4.1.2011.5.25.250.15.1.6

hwEntRedundancyVoice

INTEGER

This object indicates whether to enable the voice for redundancy transmission.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

Read-write

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction