No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPotsCircuitTestTable

hwEntPotsCircuitTestTable

This table is used to configure the circuit test.

The circuit test checks the circuit function of an analog subscriber service board, provides test conclusions for the supply voltage and voltage to ground, and provides test conclusions and measured values for the ringing current voltage, feed voltage, and loop current test results.

This table does not have any indexes.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.314.1.1

hwEntPotsCircuitTestOprType

INTEGER

This object indicates the operation type.

The options are as follows:

  • 1: stop
  • 2: start

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.1.2

hwEntPotsCircuitTestPort

Integer32

This object indicates the test port number.

bits 31-24: reserved

bits 23-16: slot index

bits 15-8: subcard index

bits 7-0: port index

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.1.3

hwEntPotsCircuitTestBusyFlag

INTEGER

This object indicates the busy test processing flag.

The options are as follows:

  • 1: cancel
  • 2: busytest
  • 3: force
  • 4: defer
  • 5: busytest

The busy test is completed by the NMS. The device does not process this enumeration. That is, when a user selects the busy test, and the host returns a message indicating that the user port is busy, the NMS records the status, delays the test for a period of time, and then performs the test for the user.

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.1.4

hwEntPotsCircuitTestTimeOut

INTEGER

This object indicates the delay of the busy test.

Value range: 1 to 1440

Default value: 30

Unit: minute

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.1.5

hwEntPotsCircuitTestTimeProc

INTEGER

This object indicates the options for handling the situation when the busy test times out.

The options are as follows:

  • 1: noTest
  • 2: mandatoryTest

Read-write

Current

1.3.6.1.4.1.2011.5.25.314.1.6

hwEntPotsCircuitTestStatus

INTEGER

This object indicates the test status.

The options are as follows:

  • 1: normal
  • 2: testfail
  • 3: portbusy
  • 4: outoftime
  • 5: testingAbnormal
  • 6: testcanceled

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.7

hwEntPotsCircuitTestDigitalVoltageResult

INTEGER

This object indicates the digital voltage test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.8

hwEntPotsCircuitTestLowBatteryResult [8]

INTEGER

This object indicates the supply low voltage test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.9

hwEntPotsCircuitTestHighBatteryResult [9]

INTEGER

This object indicates the supply high voltage test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.10

hwEntPotsCircuitTestPositiveBatteryResult

INTEGER

This object indicates the supply positive voltage test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.11

hwEntPotsCircuitTestVAGResult

INTEGER

This object indicates the A wire voltage to ground test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.12

hwEntPotsCircuitTestVBGResult

INTEGER

This object indicates the B wire voltage to ground test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.13

hwEntPotsCircuitTestLoopCurrentResult

INTEGER

This object indicates the loop current test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.14

hwEntPotsCircuitTestFeederVoltageResult

INTEGER

This object indicates the feed voltage test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.15

hwEntPotsCircuitTestRingingCurrentVoltageResult

INTEGER

This object indicates the ringing current voltage test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.16

hwEntPotsCircuitTestRingingCurrentFrequencyResult

INTEGER

This object indicates the ringing current frequency test result.

The options are as follows:

  • 1: normal
  • 2: abnormal
  • 3: notTested

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.17

hwEntPotsCircuitTestFeedervoltageValue

Integer32

This object indicates the feed voltage value.

The value is expressed in volts.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.18

hwEntPotsCircuitTestRingingCurrentVoltageValue

Integer32

This object indicates the ringing current voltage value.

The value is expressed in volts.

Read-only

Current

1.3.6.1.4.1.2011.5.25.314.1.19

hwEntPotsCircuitTestLoopCurrentValue

Integer32

This object indicates the loop current value.

Unit: milliampere

Read-only

Current

Creation Restriction

None.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation