Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwWidsProfileTable

hwWidsProfileTable

This table is used to configure device detection, attack detection, and device containment.

The index of this table is hwWidsProfileName.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.139.11.1.28.1.1

hwWidsProfileName

OCTET STRING(1–35)

not-accessible

This object indicates the name of a WIDS profile. It is the index of the table.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.5

hwWidsProfileRowStatus

RowStatus{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)}

read-write

This object indicates the row status. createAndGo(4) and destroy(6) are mainly used.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.6

hwWidsDeviceReportInterval

Unsigned32(10–3600)

read-write

This object indicates the device detection reporting interval. The default value is 300 seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.7

hwWidsDeviceSyncInterval

Unsigned32(120–360)

read-write

This object indicates the interval for APs to report all device information to an AC. The default value is 360 minutes.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.8

hwWidsSpoofProfile

OCTET STRING(0–35)

read-write

This object indicates the name of a WIDS spoof SSID profile.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.10

hwWidsBruteForceDetectInterval

Unsigned32(10–120)

read-write

This object indicates the interval for brute force attack detection. The default value is 60 seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.11

hwWidsBruteForceDetectThreshold

Unsigned32(1–100)

read-write

This object indicates the threshold for the number of brute force attack attempts, namely, the threshold for the number of key negotiation failures within a detection period. If the number of brute-force attack attempts exceeds the threshold, the terminal initiates brute force attacks. The default value is 20.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.12

hwWidsBruteForceQuietTime

Unsigned32(60–36000)

read-write

This object indicates the quiet period for brute force attack alarm reporting. The default value is 600 seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.13

hwWidsFloodDetectInterval

Unsigned32(10–120)

read-write

This object indicates the flood attack detection interval. The default value is 60 seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.14

hwWidsFloodDetectThreshold

Unsigned32(1–1000)

read-write

This object indicates the threshold for food attack detection. If the number of packets of the same type received within a detection period exceeds the threshold, flood attacks occur. The default value is 300.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.15

hwWidsFloodQuietTime

Unsigned32(60–36000)

read-write

This object indicates the quiet period for flood attack alarm reporting. The default value is 600 seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.16

hwWidsWeakIvQuietTime

Unsigned32(60–36000)

read-write

This object indicates the quiet period for weak IV attack alarm reporting. The default value is 600 seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.17

hwWidsSpoofQuietTime

Unsigned32(60–36000)

read-write

This object indicates the quiet period for spoofing attack alarm reporting. The default value is 600 seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.18

hwWidsDynamicBlackListSwitch

INTEGER{disable(1),enable(2)}

read-write

This object indicates the status of the dynamic blacklist function. The default value is 1.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.28.1.20

hwWidsStaWhitelistProfile

OCTET STRING(0–35)

read-write

hwWidsProfileTable

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

You can create entries in this table.

Modification Restriction

The profile to be bound must already exist.

Deletion Restriction

The entries in this table can be deleted.

Access Restriction

The entries in this table can be read without restriction.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 444720

Downloads: 46

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next