Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwCutAccessUserTable

hwCutAccessUserTable

This table disconnects access users.

The index of this table is hwAccessIndex.

NOTE:
This table does not support multi-node combination configuration.

OID

Object Name

Syntax

Implemented Specifications

Description

Status

1.3.6.1.4.1.2011.5.2.1.28.1

hwCutStartUserID

Integer32

read-write

This object indicates the start ID. The start ID and end ID specify a range.

current

1.3.6.1.4.1.2011.5.2.1.28.2

hwCutEndUserID

Integer32

read-write

This object indicates the end ID. The start ID and end ID specify a range.

current

1.3.6.1.4.1.2011.5.2.1.28.3

hwCutIPaddress

IpAddress

read-write

This object indicates the IP address of a user who is to be disconnected.

current

1.3.6.1.4.1.2011.5.2.1.28.4

hwCutMacAddres

MacAddress

read-write

This object indicates the MAC address of a user who is to be disconnected.

current

1.3.6.1.4.1.2011.5.2.1.28.7

hwCutDomain

DisplayString

read-write

This object indicates the domain that a user who is to be disconnected belongs to. The value is a string of 1 to 64 characters.

current

1.3.6.1.4.1.2011.5.2.1.28.14

hwCutAccessInterface

DisplayString

read-write

This object indicates the access interface of a user who is to be disconnected. The value is a string of 1 to 63 characters.

current

1.3.6.1.4.1.2011.5.2.1.28.15

hwCutUserSSID

DisplayString

read-write

This object indicates the SSID of a user who is to be disconnected. The value is a string of 1 to 32 characters.

current

1.3.6.1.4.1.2011.5.2.1.28.16

hwCutAccessSlot

Integer32

read-write

This object indicates the access slot of a user who is to be disconnected. The value is an integer.

current

1.3.6.1.4.1.2011.5.2.1.28.17

hwCutUserGroup

DisplayString

read-write

This object indicates the user group that a user who is to be disconnected belongs to. The value is a string of 1 to 64 characters.

current

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None

Translation