Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwPwe3ExtTunnelTable

hwPwe3ExtTunnelTable

This table provides the information of a tunnel table.

The indexes of this table are hwPwExtVcId, hwPwExtVcType, hwPwe3ExtPwInlabel, hwPwe3ExtPeerTnlId.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.1

hwPwExtVcId

Unsigned32

Not-accessible

The VC ID.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.2

hwPwExtVcType

HWL2VpnVcEncapsType

Not-accessible

The type of the Virtual Circuit.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.3

hwPwe3ExtPwInlabel

Unsigned32

Not-accessible

The inlabel of SVC PW.

The default value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.4

hwPwe3ExtPeerTnlId

Unsigned32

Not-accessible

The Tunnel ID.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.5

hwPwe3ExtTnlName

OCTET STRING

Read-only

The name of this Tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.6

hwPwe3ExtTnlType

Integer32 (0..255)

Read-only

The type of this Tunnel.
  • 0: LSP

  • 1: GRE

  • 2: L2TP

  • 3: IPSec

  • 4: CR LSP

  • 5: Local IFNET

  • 6: MPLS Local IFNET

  • 7: VPN QoS LSP

  • 8: IP

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.7

hwPwe3ExtTnlSrcAddress

IpAddress

Read-only

The source ip address of this tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.8

hwPwe3ExtTnlDestAddress

IpAddress

Read-only

The destination ip address of this tunnel.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.9

hwPwe3ExtLspIndex

Integer32

Read-only

The index of LSP.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.10

hwPwe3ExtLspOutIf

OCTET STRING

Read-only

The out-interface of LSP.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.11

hwPwe3ExtLspOutLabel

Integer32 (0..2147483647)

Read-only

The out-label of LSP.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.12

hwPwe3ExtLspNextHop

IpAddress

Read-only

The next-hop of LSP.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.13

hwPwe3ExtLspFec

IpAddress

Read-only

The FEC of LSP.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.14

hwPwe3ExtLspFecPfxLen

Integer32

Read-only

The length of mask for hwVplsLspFec.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.15

hwPwe3ExtLspIsBackup

TruthValue

Read-only

Indicate whether the LSP is main.

The default value is false.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.16

hwPwe3ExtPwOutLabel

Integer32

Read-only

The outlabel of PW, specified for SVC.

The default value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.17

hwPwe3ExtIsBalance

TruthValue

Read-only

Property of Balance.

The default value is false.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.18

hwPwe3ExtLspTunnelId

Integer32

Read-only

Tunnel ID used by the PW.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.19

hwPwe3ExtLspSignType

INTEGER

Read-only

Signaling used for establishing a tunnel.

  • 1: LDP
  • 2: CRLDP
  • 3: RSVP
  • 4: BGP
  • 5: L3VPN
  • 6: Static
  • 7: CRStatic
  • 8: BGPIPv6
  • 9: StaticHA
  • 10: L2VPNIPv6
  • 20: maxSignal

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.5.1.2.1.50

hwPwe3ExtTnlRowStatus

RowStatus

Read-only

The operating state of the row.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The entries in this table cannot be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.