Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
mplsTunnelUp

mplsTunnelUp

OID

Object Name

Binding Variable

Description

Implemented Specifications

1.3.6.1.2.1.10.166.3.0.1

mplsTunnelUp

  • mplsTunnelAdminStatus
  • mplsTunnelOperStatus

This notification is generated when an mplsTunnelOperStatus object for one of the configured tunnels is about to leave the down state and transition into some other state (but not into the notPresent state).

This other state is indicated by the included value of mplsTunnelOperStatus.

Currently, binding variables ifName, hwmplsTunnelInterfaceName and mplsTunnelDownReason are added.