Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntBraPortOperTable

hwEntBraPortOperTable

This table is used to maintain and query BRA port status and uses S/S/P as the index for this port.

The index of this table is hwEntBraPortOperIndex.

The table entry of this table is hwEntBraPortOperEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.252.4.1.1

hwEntBraPortOperIndex

Integer32

This object indicates the port index.

Not-accessible

Current

1.3.6.1.4.1.2011.5.25.252.4.1.2

hwEntBraPortSrvState

INTEGER

This object indicates the physical status.

The options are as follows:

  • 1: normal
  • 2: fault
  • 3: deactive
  • 4: powerdeny

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.4.1.3

hwEntBraPortAdminState

INTEGER

This object indicates the management status.

The options are as follows:

  • 1: noLoopNoTest
  • 2: noLoopTest
  • 3: localLoopNoTest
  • 4: localLoopTest
  • 5: remoteLoopTest

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.4.1.4

hwEntBraPortAlarmState

BITS

This object indicates the alarm status.

bit0: LT overflow

bit1: S interface fault (EI2)

bit2: U interface fault (LOS/RSY)

bit3: S interface deactivation (SAI)

bit4: U interface deactivation (ACT)

NOTE:

If the bit value is 0, there is no alarm. If the bit value is 1, there is an alarm.

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.4.1.5

hwEntBraPortAdminOper

INTEGER

This object indicates the port operations.

The options are as follows:

  • 1: remoteLoop
  • 2: localLoop
  • 3: cancelLoop

Read-write

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction

The entries in this table cannot be deleted.