Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwTwampSenderOperTable

hwTwampSenderOperTable

This table is used to query the running status of test sessions.

The index of this table is hwTwampSenderId.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.1

hwTwampSenderOperState

INTEGER{inactive(1),active(2)}

Read-only

The value of this object identifies the running status of a test session.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.2

hwTwampSenderOperType

INTEGER{continual(1),onDemand(2)}

Read-only

The value of this object identifies the test type of a test session.

  • 1: proactive measurement
  • 2: on-demand measurement

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.3

hwTwampSenderOperInactiveReason

INTEGER{notStart(1),absenceResource(2),boardFault(3),null(99)}

Read-only

The value of this object identifies the cause for an unstarted test session.

  • 1: The test session is not started.
  • 2: The board resources are insufficient.
  • 3. The board is faulty.
  • 99: The test session has been started.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.4

hwTwampSenderOperLastStartTime

DateAndTime

Read-only

This object indicates the time when a test session is recently started.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.5

hwTwampSenderOperLastStopTime

DateAndTime

Read-only

This object indicates the time when a test session is recently stopped.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.6

hwTwampSenderOperTxCount

Counter64

Read-only

This object indicates the number of sent packets.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.7

hwTwampSenderOperRxCount

Counter64

Read-only

This object indicates the number of received packets.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.8

hwTwampSenderOperDiscardCount

Counter64

Read-only

This object indicates the number of dropped packets.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.333.1.1.5.1.9

hwTwampSenderOperSequence

Gauge32

Read-only

This object indicates the sequence number of a test session.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The sessions that are not started are not displayed in this table.