No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntVe1PortOperTable

hwEntVe1PortOperTable

This table is used to maintain and query VE1 port status and uses S/S/P as the index for this port.

The index of this table is hwEntVe1PortOperIndex.

The table entry of this table is hwEntVe1PortOperEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.252.6.1.1

hwEntVe1PortOperIndex

Integer32

This object indicates the port operation index.

not-accessible

current

1.3.6.1.4.1.2011.5.25.252.6.1.2

hwEntVe1PortSrvState

INTEGER

This object indicates the physical status.

The options are as follows:

  • 1: normal
  • 2: fault
  • 3: lineAbnormal
  • 4: powerdeny

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.6.1.3

hwEntVe1PortAdminState

INTEGER

This object indicates the management status.

The options are as follows:

  • 1: noLoopNoTest
  • 2: noLoopTest
  • 3: localLoopNoTest
  • 4: localLoopTest
  • 5: remoteLoopNoTest
  • 6: remoteLoopTest

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.6.1.4

hwEntVe1PortWarningState

BITS

This object indicates the line alarm status.

bit0: LOS alarm

bit1: AIS alarm

bit2: LFA alarm

bit3: LMFA alarm

bit4: RRA alarm

bit5: CRCER alarm

bit6: SCOL alarm

bit7: ULF alarm

bit8: OLF alarm

bit9: LDT alarm

bit10: alarm about the downlink error code second

bit11: alarm about the uplink error code second

bit12: alarm about downlink serious error second

bit13: alarm about uplink serious error second

bit14: alarm about the downlink degrading minute

bit15: alarm about the uplink degrading minute

NOTE:

If the bit value is 0, there is no alarm. If the bit value is 1, there is an alarm.

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.6.1.5

hwEntVe1PortAdminOper

INTEGER

This object indicates the port operations.

The options are as follows:

  • 1: remoteLoop
  • 2: localLoop
  • 3: cancelLoop

Read-write

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 452026

Downloads: 48

Average rating: