MIB Reference

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxTrkGrpRunningTable

hwEntPbxTrkGrpRunningTable

This table allows users to query the running status of a trunk group.

The index of this table is hwEntPbxTrkGrpRunningTrkGrpName.

The table entry of this table is hwEntPbxTrkGrpRunningEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.313.12.1.1

hwEntPbxTrkGrpRunningTrkGrpName

OCTET STRING

This object indicates the name of a trunk group.

Length: a string of 1 to 32 characters

not-accessible

current

1.3.6.1.4.1.2011.5.25.313.12.1.2

hwEntPbxTrkGrpRunningState

INTEGER

This object indicates the running status of a trunk group.

The options are as follows:

  • 1: normal
  • 2: waitack
  • 3: closed
  • 4: fail
  • 5: unknown

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.3

hwEntPbxTrkGrpRunningSipRegState

INTEGER

This object indicates the SIP trunk group registration state.

The options are as follows:

  • 1: outSservice
  • 2: inSservice

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.4

hwEntPbxTrkGrpRunningSignalType

INTEGER

This object indicates the trunk signaling protocol type.

The options are as follows:

  • 1: dss1Net
  • 2: dss1User
  • 3: fxo
  • 4: sip
  • 5: qsigNet
  • 6: qsigUser
  • 7: e1r2
  • 8: h323

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.5

hwEntPbxTrkGrpRunningDesc

OCTET STRING

This object indicates the description of a trunk group.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.6

hwEntPbxTrkGrpRunningSelectMode

INTEGER

This object indicates the circuit selection mode.

The options are as follows:

  • 1: loop
  • 2: increase
  • 3: decrease
  • l4:master
  • l5:portloop
  • l6:portincrease

Default value: loop

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.7

hwEntPbxTrkGrpRunningEnterprise

OCTET STRING

This object indicates an enterprise name.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.8

hwEntPbxTrkGrpRunningDnSet

OCTET STRING

This object indicates the DN set.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.9

hwEntPbxTrkGrpRunningCountryCode

OCTET STRING

This object indicates the country or region code.

Length: a string of 1 to 4 digits

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.10

hwEntPbxTrkGrpRunningAreaCode

OCTET STRING

This object indicates the area code.

Length: a string of 1 to 8 digits

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.11

hwEntPbxTrkGrpRunningInRight

INTEGER

This object indicates the incoming call permission.

The options are as follows:

  • 1: internal
  • 2: local
  • 3: nationalToll
  • 4: internationalToll
  • 5: noRight

By default, only local users have the incoming call permission.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.12

hwEntPbxTrkGrpRunningOutRight

INTEGER

This object indicates the outgoing call permission.

The options are as follows:

The options are as follows:

  • 1: internal
  • 2: local
  • 3: nationalToll
  • 4: internationalToll
  • 5: noRight

By default, only local users can be called.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.13

hwEntPbxTrkGrpRunningPraStandard

INTEGER

This object indicates the PRA protocol standard.

The options are as follows:

  • 1: q931
  • 2: nfas
  • 3: csc
  • 4: ni1

Default value: q931

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.14

hwEntPbxTrkGrpRunningIpGrpRegMode

INTEGER

This object indicates the SIP trunk group registration mode.

The options are as follows:

  • 1: noRegister
  • 2: trunkGroup
  • 3: trunkCircuit

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.15

hwEntPbxTrkGrpRunningSignallingIP

IpAddress

This object indicates the local signaling IP address.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.16

hwEntPbxTrkGrpRunningSignallingPort

Integer32

This object indicates the local signaling port number.

Value range: 5000 to 5999

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.17

hwEntPbxTrkGrpRunningMediaIP

IpAddress

This object indicates the local media IP address.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.18

hwEntPbxTrkGrpRunningIpGrpPeerAddrMode

INTEGER

This object indicates the mode in which the peer IP address is obtained.

The options are as follows:

  • 1: static
  • 2: dnsA
  • 3: dnsSrv
  • 4: dnsNaptr

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.19

hwEntPbxTrkGrpRunningPrimaryPeerIP

IpAddress

This object indicates the IP address of the primary peer device.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.20

hwEntPbxTrkGrpRunningPrimaryPeerPort

Integer32

This object indicates the port number of the primary peer device.

Value range:

1 to 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.21

hwEntPbxTrkGrpRunningPeerSecondaryIP

Integer32

This object indicates the IP address of the secondary peer device.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.22

hwEntPbxTrkGrpRunningPeerSecondaryPort

Integer32

This object indicates the port number of the secondary peer device.

Value range:

1 to 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.23

hwEntPbxTrkGrpRunningPrimaryPeerDomain

OCTET STRING

This object indicates the domain name of the primary peer device.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.24

hwEntPbxTrkGrpRunningIpGrpPeerSecondaryDomain

OCTET STRING

This object indicates the domain name of the secondary peer device.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.25

hwEntPbxTrkGrpRunningMaxCallNum

Integer32

This object indicates the maximum number of concurrent calls in a trunk group.

Value range:

1 to 65535

Default value: 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.26

hwEntPbxTrkGrpRunningTransfer

INTEGER

This object indicates the transmission mode.

The options are as follows:

  • 1: tcp
  • 2: udp
  • 3: sctp
  • 4: tls

Default value: udp

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.27

hwEntPbxTrkGrpRunningRegUri

OCTET STRING

This object indicates the registrar server.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.28

hwEntPbxTrkGrpRunningHomeDomain

OCTET STRING

Indicates the home domain name.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.29

hwEntPbxTrkGrpRunningMgcType

INTEGER

This object indicates the adaptation type.

The options are as follows:

  • 1: mg
  • 2: mgc

Default value: mg

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.30

hwEntPbxTrkGrpRunningRegID

OCTET STRING

This object indicates the identifier of a trunk group.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.31

hwEntPbxTrkGrpRunningRegPwdType

INTEGER

This object indicates the password type.

The options are as follows:

  • 1: simple
  • 2: cipher

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.32

hwEntPbxTrkGrpRunningRegPwd

OCTET STRING

This object indicates the trunk authentication password.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.33

hwEntPbxTrkGrpRunningDefaultCallerNum

OCTET STRING

This object indicates the default number displayed.

Length: a string of 1 to 32 digits

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.34

hwEntPbxTrkGrpRunningDynSignallingIPName

OCTET STRING

This object indicates the dynamic signaling IP name.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.35

hwEntPbxTrkGrpRunningDynMediaIPName

OCTET STRING

This object indicates the dynamic media IP name.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.36

hwEntPbxTrkGrpRunningCSmode

INTEGER

This object indicates the client/server mode.

The options are as follows:

  • 1: client
  • 2: server
  • 3: client_server

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.37

hwEntPbxTrkGrpRunningMediaProxy

INTEGER

This object indicates the media proxy policy.

The options are as follows:

  • 1: disable
  • 2: enable
  • 3: auto

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.38

hwEntPbxTrkGrpRunningMappedSignallingIP

IpAddress

This object indicates the mapped public signaling IP address.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.39

hwEntPbxTrkGrpRunningMappedSignallingPort

Integer32

This object indicates the mapped public signaling port number.

Value range: 1 to 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.40

hwEntPbxTrkGrpRunningMappedMediaIP

IpAddress

This object indicates the mapped public media IP address.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.41

hwEntPbxTrkGrpRunningMappedMediaPortStart

Integer32

This object indicates the mapped start media port number.

Value range: 1 to 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.42

hwEntPbxTrkGrpRunningMappedMediaProxyPortStart

Integer32

This object indicates the mapped start media proxy port number.

Value range: 1 to 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.43

hwEntPbxTrkGrpRunningR2Profile

OCTET STRING

This object indicates the name of the R2 signaling profile.

Length: a string of 1 to 32 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.44

hwEntPbxTrkGrpRunningR2IsEarlyMedia

INTEGER

This object indicates whether the R2 trunk receives early media.

The options are as follows:

  • 1: disable
  • 2: enable

Default value: disable

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.45

hwEntPbxTrkGrpRunningR2PlayRingback

INTEGER

This object indicates whether to play RBTs to the peer end.

The options are as follows:

  • 1: disable
  • 2: enable

Default value: enable

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.46

hwEntPbxTrkGrpRunningBusyNum

Integer32

This object indicates the number of busy trunks in a trunk group.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.47

hwEntPbxTrkGrpRunningIdleNum

Integer32

This object indicates the number of idle trunks in a trunk group.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.48

hwEntPbxTrkGrpRunningFaultNum

Integer32

This object indicates the number of faulty trunks in a trunk group.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.49

hwEntPbxTrkGrpRunningMediaBandwidthControlSwitch

INTEGER

This object indicates whether to enable conventional media bandwidth control on a bandwidth trunk group. The values are as follows:

  • 1: disable
  • 2: enable

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.50

hwEntPbxTrkGrpRunningMaxBandwidth

Integer32

This object indicates the maximum conventional media bandwidth on a bandwidth trunk group, in 100 kbit/s.

The value ranges from 1 to 5000.

read-only

current

1.3.6.1.4.1.2011.5.25.313.12.1.51

hwEntPbxTrkGrpRunningR2ReAnswer

INTEGER

The calling party control right of the R2 trunk.

The options are as follows:

  • 1: disable
  • 2: enable

read-only

current

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.

Translation
Download