Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxSIPServerRunningTable

hwEntPbxSIPServerRunningTable

This table displays the running status of the SIP server.

The index of this table is hwEntPbxSIPServerRunningSIPServerIndex.

The table entry of this table is hwEntPbxSIPServerRunningEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.313.9.1.1

hwEntPbxSIPServerRunningSIPServerIndex

Integer32

This object indicates the index of the SIP server.

Currently, only one SIP server is supported. The index is fixed as 0.

not-accessible

current

1.3.6.1.4.1.2011.5.25.313.9.1.2

hwEntPbxSIPServerRunningSignallingIP

IpAddress

This object indicates the signaling IP address.

read-only

Current

1.3.6.1.4.1.2011.5.25.313.9.1.3

hwEntPbxSIPServerRunningSignallingPort

Integer32

This object indicates the signaling port number.

Value range: 5000 to 5999

read-only

Current

1.3.6.1.4.1.2011.5.25.313.9.1.4

hwEntPbxSIPServerRunningMediaIP

IpAddress

This object indicates the media IP address.

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.5

hwEntPbxSIPServerRunningRegUri

OCTET STRING

This object indicates the registrar URI.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.6

hwEntPbxSIPServerRunningHomeDomain

OCTET STRING

Indicates the home domain name.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.7

hwEntPbxSIPServerRunningSignalDomain

OCTET STRING

This object indicates the signaling domain name.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.8

hwEntPbxSIPServerRunningDdnsClientName

OCTET STRING

This object indicates the DDNS client name for the updated DDNS domain address.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.9

hwEntPbxSIPServerRunningDynSignallingIPName

OCTET STRING

This object indicates the dynamic signaling IP name.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.10

hwEntPbxSIPServerRunningDynMediaIPName

OCTET STRING

This object indicates the dynamic media IP name.

Length: a string of 1 to 64 characters

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.11

hwEntPbxSIPServerRunningTransfer

INTEGER

This object indicates the transmission mode.

The options are as follows:

  • 1: tcp
  • 2: udp
  • 3: sctp
  • 4: tls

Default value: udp

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.12

hwEntPbxSIPServerRunningCSmode

INTEGER

This object indicates the client/server mode.

The options are as follows:

  • 1: server
  • 2: client_server

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.13

hwEntPbxSIPServerRunningSignallingProxy

INTEGER

This object indicates the signaling proxy policy.

The options are as follows:

  • 1: disable
  • 2: enable
  • 3: auto

Default value: disable

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.14

hwEntPbxSIPServerRunningMediaProxy

INTEGER

This object indicates the media proxy policy.

The options are as follows:

  • 1: disable
  • 2: enable
  • 3: auto

Default value: disable

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.15

hwEntPbxSIPServerRunningMappedSignallingIP

IpAddress

This object indicates the mapped public signaling IP address.

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.16

hwEntPbxSIPServerRunningMappedSignallingPort

Integer32

This object indicates the mapped public signaling port number.

Value range: 1 to 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.17

hwEntPbxSIPServerRunningMappedMediaIP

IpAddress

This object indicates the mapped public media IP address.

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.18

hwEntPbxSIPServerRunningMappedMediaPortStart

Integer32

This object indicates the mapped start media port number.

Value range: 1 to 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.19

hwEntPbxSIPServerRunningMappedMediaProxyPortStart

Integer32

This object indicates the mapped start media proxy port number.

Value range: 1 to 65535

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.20

hwEntPbxSIPServerRunningState

INTEGER

This object indicates the SIP server status.

The options are as follows:

  • 1: normal
  • 2: waitack
  • 3: closed
  • 4: fail
  • 5: unknown

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.21

hwEntPbxSIPServerRunningMediaBandwidthControlSwitch

INTEGER

This object indicates whether to enable conventional media bandwidth control on the SIP server.

The values are as follows:

  • 1: disable
  • 2: enable

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.22

hwEntPbxSIPServerRunningMaxBandwidth

Integer32

This object indicates the maximum conventional media bandwidth on the SIP server, in 100 kbit/s.

The value ranges from 1 to 5000.

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.23

hwEntPbxSIPServerRunningMediaProxyMediaBandwidthControlSwitch

INTEGER

This object indicates whether to enable media bandwidth control when the SIP server serves as the media proxy.

The values are as follows:

  • 1: disable
  • 2: enable

read-only

current

1.3.6.1.4.1.2011.5.25.313.9.1.24

hwEntPbxSIPServerRunningMediaProxyMaxBandwidth

Integer32

This object indicates the maximum media bandwidth when the SIP server serves as the media proxy, in 100 kbit/s.

The value ranges from 1 to 5000.

read-only

current

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.