MIB Reference

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwY1731TestIdSingleSynEndedLMSendTable

hwY1731TestIdSingleSynEndedLMSendTable

This table is used to create and configure send information for single-ended SLM.

The index of this table is hwY1731TestIdentifier.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.136.1.8.1.16.1.1

hwY1731TestIdSingleSynEndedLMSendIsContinue

TruthValue

read-create

This object indicates whether proactive single-ended SLM is used.

  • true: Proactive single-ended SLM is used.
  • false: On-demand single-ended SLM is used.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.1.16.1.2

hwY1731TestIdSingleSynEndedLMSendInterval INTEGER

{

invalid(1),

interval1s(2),

interval10s(3),

interval3Dot3ms(4),

interval10ms(5),

interval100ms(6)

}

read-create

This object indicates the interval at which SLM messages are sent.

  • invalid: invalid
  • interval1s: 1s
  • interval10s: 10s
  • interval3Dot3ms: 3.3 ms
  • interval10ms: 10 ms
  • interval100ms: 100 ms

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.1.16.1.3

hwY1731TestIdSingleSynEndedLMSendCount Integer32 (0 | 1..1000)

read-create

This object indicates the number of frames sent for single-ended SLM.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.1.16.1.4

hwY1731TestIdSingleSynEndedLMSendTimeOut Integer32 (0 | 1..10)

read-create

This object indicates the timeout period for waiting for an SLR message.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.1.16.1.5

hwY1731TestIdSingleSynEndedLMSendRowStatus RowStatus

read-create

This object indicates the row status, which can be CreateAndGo or destroy.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.1.16.1.6

hwY1731TestIdSingleSynEndedLMSendPacketSize

Integer32 (0 | 64..1518)

read-create

This object indicates the length of frames in single-ended synthetic frame loss measurement.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.1.16.1.7

hwY1731TestIdSingleSynEndedLMSendMeasureMentCount

Integer32 (0 | 1..60)

read-create

This object indicates the number of rounds for performing single-ended synthetic frame loss measurement.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

You can create entries in this table only after a test instance ID has been created.

Modification Restriction

Entries in this table cannot be modified.

Deletion Restriction

Entries in this table can be deleted only after CFM has been enabled globally.

Access Restriction

Entries in this table can be read only after CFM has been enabled globally.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 505435

Downloads: 49

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next