Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwDot3ahEfmEventConfigTable

hwDot3ahEfmEventConfigTable

This table is used to manage the configuration of events on the interfaces.

The index of this table is ifIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.1

hwDot3ahEfmErrSymPeriodWindowHi

Unsigned32

Read-write

This object indicates that the high four bits and low four bits are used together to indicate the interval for monitoring error codes. It is represented by the number of frames per unit of time. The default value of the interval for monitoring error codes is one second.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.2

hwDot3ahEfmErrSymPeriodWindowLo

Unsigned32

Read-write

This object indicates that the high four bits and low four bits are used together to indicate the interval for monitoring error codes. It is represented by the number of frames per unit of time. The default value of the interval for monitoring error codes is one second.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.3

hwDot3ahEfmErrSymPeriodThresholdHi

Unsigned32

Read-write

This object indicates that the high four bits and low four bits are used together to indicate the threshold of error codes. The default value is 1. The threshold can be set to 0. At this time, the threshold-crossing alarm is reported periodically. It is used to asynchronously notify the threshold-crossing alarm to the peer.

It is not recommended to set as zero.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.4

hwDot3ahEfmErrSymPeriodThresholdLo

Unsigned32

Read-write

This object indicates that the high four bits and low four bits are used together to indicate the threshold of error codes. The default value is 1. The threshold can be set to 0. At this time, the threshold-crossing alarm is reported periodically. It is used to asynchronously notify the threshold-crossing alarm to the peer.

It is not recommended to set as zero.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.5

hwDot3ahEfmErrSymPeriodEvNotifEnable

TruthValue

Read-write

This object indicates whether the OAMPD event notification is enabled when the threshold is crossed. The value can be:
  • true

  • false

By default, the value is false.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.9

hwDot3ahEfmErrFrameWindow

Unsigned32

Read-write

This object indicates the monitoring interval. The unit is 100 ms. By default, the value is 10 (1 second).

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.10

hwDot3ahEfmErrFrameThresHold

Unsigned32

Read-write

This object indicates that the threshold value, which is 1 by default, can be set to 0. At this time, the threshold-crossing alarm is reported periodically. It is used to asynchronously notify the threshold-crossing alarm to the peer.

It is not recommended to set as zero.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.11

hwDot3ahEfmErrFrameEvNotifEnable

TruthValue

Read-write

This object indicates whether the OAMPD event notification is enabled when the threshold is crossed. The value can be:
  • true

  • false

By default, the value is false.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.12

hwDot3ahEfmErrFrameSecsSummaryWindow

Integer32 (100..9000)

Read-write

This object indicates the statistics interval. The unit is 100 ms. By default, the value is 600 (60 seconds). The value ranges from 100 to 9000.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.13

hwDot3ahEfmErrFrameSecsSummaryThreshold

Integer32 (0..900)

Read-write

The value ranges from 0 to 900. The default value is 1. It can be set to 0.

It is not recommended to set as zero.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.14

hwDot3ahEfmErrFrameSecsEvNotifEnable

TruthValue

Read-write

This object indicates whether the OAMPD event notification is enabled when the threshold is crossed. The value can be:
  • true

  • false

By default, the value is false.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.17

hwDot3ahEfmThresholdTriggerErrDown

EnabledStatus

Read-write

The value of this object identifies whether an EFM OAM threshold crossing event is associated with an interface. The value can be:
  • enabled: indicates that an EFM OAM threshold crossing event is associated with an interface. In this case, when EFM OAM detects an errored frame event, an errored code event, or an errored frame seconds summary event, the system sets the administrative status of the interface Down.

  • disabled: indicates that an EFM OAM threshold crossing event is not associated with an interface.

By default, the value is disabled.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

The entries in this table can be created only after EFM is enabled globally.

Modification Restriction

The entries in this table can be modified only after EFM is enabled globally.

Deletion Restriction

None.

Access Restriction

The entries in this table can be read only after EFM is enabled globally.