No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntSipAgConfigTable

hwEntSipAgConfigTable

This table is used to configure SIP AG parameters.

The index of this table is hwEntSipAgId.

The table entry of this table is hwEntSipAgConfigEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.250.1.1.1

hwEntSipAgId

Integer32

This object indicates the ID of a SIP AG interface.

Value range: 0 to 16777215

Not-accessible

Current

1.3.6.1.4.1.2011.5.25.250.1.1.2

hwEntSipAgMediaIPAddress

IpAddress

This object indicates the media IP address.

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.3

hwEntSipAgSignallingIPAddress

IpAddress

This object indicates the signaling IP address.

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.4

hwEntSipAgSignallingPort

Integer32

This object indicates the signaling port number.

Value range: 5000 to 5999

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.5

hwEntSipAgMediaAddrName

OCTET STRING

This object indicates the dynamic media IP address name.

Length: a string of 1 to 64 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.6

hwEntSipAgSignallingAddrName

OCTET STRING

This object indicates the dynamic signaling IP address name.

Length: a string of 1 to 64 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.7

hwEntSipAgTransMode

INTEGER

This object indicates the transmission mode.

The options are as follows:

  • 1: tcp
  • 2: udp
  • 3: sctp

Default value: udp

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.8

hwEntSipAgDomainName

OCTET STRING

This object indicates the AG server domain name.

Length: a string of 1 to 64 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.9

hwEntSipAgHomeDomainName

OCTET STRING

This object indicates the AG home domain name.

Length: a string of 1 to 64 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.10

hwEntSipAgRegisterUri

OCTET STRING

This object indicates the URI of the registration server.

Length: a string of 1 to 64 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.11

hwEntSipAgConferenceFactoryUri

OCTET STRING

This object indicates the URI of the conference factory.

Length: a string of 1 to 64 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.12

hwEntSipAgDesc

OCTET STRING

This object indicates the SIP AG interface description.

Length: a string of 1 to 32 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.13

hwEntSipAgPhoneContext

OCTET STRING

This object indicates the SIP AG phone context.

Length: a string of 1 to 32 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.14

hwEntSipAgRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

Currently, only createAndGo and destroy are supported.

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.15

hwEntSipAgAdminStatus

INTEGER

This object indicates the interface management operation type.

The options are as follows:

  • 1: reset
  • 2: switchover

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.16

hwEntSipAgSwitchoverDestination

INTEGER

This object indicates the switchover destination.

The options are as follows:

  • 1: primary
  • 2: secondary

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.17

hwEntSipAgProfileIndex

Integer32

This object indicates a profile index.

Value range: 0 to 3

Default value: 1

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.18

hwEntSipAgProfileName

OCTET STRING

This object indicates a profile name.

Length: a string of 0 to 32 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.19

hwEntSipAgSrvLogicIndex

Integer32

This object indicates a service logic index.

Value range: 0 to 9

Default value: 0

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.20

hwEntSipAgSrvLogicName

OCTET STRING

This object indicates a service logic name.

Length range: 0 to 32

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.21

hwEntSipAgServerDhcpOption

INTEGER

This object indicates the DHCP option.

The options are as follows:

  • 1: none
  • 2: option120
  • 3: option21

Default value: none

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.22

hwEntSipAgAuthMode

INTEGER

This object indicates the user authentication mode.

The options are as follows:

  • 1: interface
  • 2: user

Default value: user

NOTE:

interface: Users corresponding to the same interface uses the same authentication user name.

user: Each user has an individual IMPI.

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.23

hwEntSipAgAuthUserName

OCTET STRING

This object indicates the user name for security authentication.

Length: a string of 0 to 64 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.24

hwEntSipAgAuthPasswordMode

INTEGER

This object indicates the password mode for security authentication.

The options are as follows:

  • 1: password
  • 2: ha1

Default value: password

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.25

hwEntSipAgAuthPassword

OCTET STRING

This object indicates the security authentication password.

Length: a string of 0 to 64 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.26

hwEntSipAgAuthHA1

OCTET STRING

This object indicates the security authentication HA1 password.

Length: a string of 0 to 32 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.27

hwEntSipAgSubUAProfile

INTEGER

This object indicates whether to subscribe to UA-PROFILE.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: enable

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.28

hwEntSipAgSubRegState

INTEGER

This object indicates whether to subscribe to REG-STATE.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.29

hwEntSipAgSubMwi

INTEGER

This object indicates whether to subscribe to the MWI.

The options are as follows:

  • 1: enable
  • 2: disable

Default value: disable

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.30

hwEntSipAgSdpNegoMode

INTEGER

This object indicates the SDP negotiation mode.

The options are as follows:

  • 1: local
  • 2: remote

Default value: remote

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.31

hwEntSipAgProxyDualHome

INTEGER

This object indicates whether to support the proxy dual-homing mode.

The options are as follows:

  • 1: no
  • 2: dualhome
  • 3: autoswitchover

Default value: dualhome

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.32

hwEntSipAgProxyDetectMode

INTEGER

This object indicates the proxy detection mode.

The options are as follows:

  • 1: option
  • 2: probe
  • 3: register

Default value: probe

Read-create

Current

1.3.6.1.4.1.2011.5.25.250.1.1.33

hwEntSipAgProxyRefreshMode

INTEGER

This object indicates the proxy address update mode.

The options are as follows:

  • 1: immediate
  • 2: defer
  • 3: noswitch
  • 255: null

Read-create

Current

Creation Restriction

None.

Modification Restriction

None.

Deletion Restriction

Entries cannot be deleted in the following cases:

  • Users have been configured for the interface.
  • The interface is being reset.
  • Other command line users perform operations under this interface.

Access Restriction

None.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 513710

Downloads: 49

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next